Historic masonry structures located in dense urban environments are increasingly exposed to anthropogenic dynamic loads generated during large public events. Among these loads, synchronized crowd movements during con- certs can produce low-frequency ground vibrations capable of affecting nearby heritage structures. This study investigates the structural response of the medie- val Moletta Tower located in Circus Maximus in Rome, Italy, under anthropic vibrations induced by large concert events. A calibrated three-dimensional fi- nite element model of the tower and surrounding soil was developed and cali- brated using monitoring data collected during several concerts. Dynamic simu- lations were performed to evaluate the impact of synchronized crowd jumping on the structural response of the tower. The results show that crowd-induced vibrations can exceed recommended vibration thresholds when more than ap- proximately 36,000 individuals jump simultaneously. In addition, nonlinear analysis reveals the formation of localized plastic hinges at the base of the tow- er for crowd sizes exceeding 50,000 participants. To mitigate these vibrations, three strategies were investigated: a Tuned Mass Damper Inerter installed in the tower, vibration-damping foam mats placed in the audience area, and subsur- face geofoam barriers designed to interrupt wave propagation through the soil. Comparative analysis shows that foam-based vibration-damping mats provide the highest attenuation, reducing peak accelerations by up to 60%, while geofoam barriers and TMDI systems achieve reductions between 15-45% and 10-40%, respectively.
Vibration Impact of Large Crowd Events on Historic Masonry Towers and Mitigation Strategies: The Case of the Moletta Tower at Circus Maximus / Bali, A., Cardoni, A., Louar, M.A., Cimellaro, G.P.. - 944:(2026), pp. 874-883. (3rd International Conference on Resilience, Earthquake Engineering and Structural Health Monitoring, ICONREM 2024 Firenze (Ita) 16-19 June 2026) [10.1007/978-3-032-39867-3_82].
Vibration Impact of Large Crowd Events on Historic Masonry Towers and Mitigation Strategies: The Case of the Moletta Tower at Circus Maximus
Bali A.;Cardoni A.;Cimellaro G. P.
2026
Abstract
Historic masonry structures located in dense urban environments are increasingly exposed to anthropogenic dynamic loads generated during large public events. Among these loads, synchronized crowd movements during con- certs can produce low-frequency ground vibrations capable of affecting nearby heritage structures. This study investigates the structural response of the medie- val Moletta Tower located in Circus Maximus in Rome, Italy, under anthropic vibrations induced by large concert events. A calibrated three-dimensional fi- nite element model of the tower and surrounding soil was developed and cali- brated using monitoring data collected during several concerts. Dynamic simu- lations were performed to evaluate the impact of synchronized crowd jumping on the structural response of the tower. The results show that crowd-induced vibrations can exceed recommended vibration thresholds when more than ap- proximately 36,000 individuals jump simultaneously. In addition, nonlinear analysis reveals the formation of localized plastic hinges at the base of the tow- er for crowd sizes exceeding 50,000 participants. To mitigate these vibrations, three strategies were investigated: a Tuned Mass Damper Inerter installed in the tower, vibration-damping foam mats placed in the audience area, and subsur- face geofoam barriers designed to interrupt wave propagation through the soil. Comparative analysis shows that foam-based vibration-damping mats provide the highest attenuation, reducing peak accelerations by up to 60%, while geofoam barriers and TMDI systems achieve reductions between 15-45% and 10-40%, respectively.| File | Dimensione | Formato | |
|---|---|---|---|
|
Full paper ICONREM.pdf
embargo fino al 13/10/2027
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
935.87 kB
Formato
Adobe PDF
|
935.87 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.