This study assesses bond wire degradation differences between DC and AC power cycling tests in IGBT power modules. With existing experimental data, an empirical lifetime model has been developed for both methods. With the bond wire lift-off being the main failure mechanism, physical modeling approach is applied using a simplified thermo-mechanical finite element model to examine the temperature evolution, stress and strain development at the bond wire-chip interface. Factors including heating time, temperature gradient, and current density are addressed and discussed to explain the number of cycles to failure difference between the two power cycling test methods.
Comparative Analysis of Bond Wire Degradation in Power Modules during DC and AC Power Cycling / Zhang, Kaichen; Iannuzzo, Francesco; Blaabjerg, Frede. - ELETTRONICO. - (2024). (Intervento presentato al convegno 2024 IEEE 15th International Symposium on Power Electronics for Distributed Generation Systems, PEDG 2024 nel 23/06/2024 - 26/06/2024) [10.1109/PEDG61800.2024.10667438].
Comparative Analysis of Bond Wire Degradation in Power Modules during DC and AC Power Cycling
Francesco Iannuzzo;
2024
Abstract
This study assesses bond wire degradation differences between DC and AC power cycling tests in IGBT power modules. With existing experimental data, an empirical lifetime model has been developed for both methods. With the bond wire lift-off being the main failure mechanism, physical modeling approach is applied using a simplified thermo-mechanical finite element model to examine the temperature evolution, stress and strain development at the bond wire-chip interface. Factors including heating time, temperature gradient, and current density are addressed and discussed to explain the number of cycles to failure difference between the two power cycling test methods.| File | Dimensione | Formato | |
|---|---|---|---|
| 
									
										
										
										
										
											
												
												
												    
												
											
										
									
									
										
										
											Comparative_Analysis_of_Bond_Wire_Degradation_in_Power_Modules_During_DC_and_AC_Power_Cycling_compressed.pdf
										
																				
									
										
											 accesso riservato 
											Tipologia:
											2a Post-print versione editoriale / Version of Record
										 
									
									
									
									
										
											Licenza:
											
											
												Non Pubblico - Accesso privato/ristretto
												
												
												
											
										 
									
									
										Dimensione
										349.28 kB
									 
									
										Formato
										Adobe PDF
									 
										
										
								 | 
								349.28 kB | Adobe PDF | Visualizza/Apri Richiedi una copia | 
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2999705
			
		
	
	
	
			      	