In this paper, we propose the design and experimental validation of an electro-hydrostatic actuator, as an alternative to traditional actuation technologies, for a powered knee prosthesis. The aim is to demonstrate that the adopted system-level design yields a highly integrated, lightweight, back-drivable device able to satisfy the biomechanical torque and speed requirements of the knee. Moreover, the back-drivable nature of the actuators allows for active and regenerative operations in the four quadrants of the torque-speed plane. In the context of knee biomechanics, this could lead to a potential advantage with respect to other powered prosthetic solutions, in terms of power consumption and device autonomy. Different control strategies, such as position, admittance and regenerative braking controllers, are implemented and tested on a dedicated rig to validate the design choices and demonstrate the prosthesis functionality and performance.

Knee prosthesis powered by a fully integrated and highly back-drivable electro-hydrostatic actuator / Tessari, Federico; Galluzzi, Renato; Tonoli, Andrea; Amati, Nicola; De Michieli, Lorenzo; Laffranchi, Matteo. - In: MECHATRONICS. - ISSN 0957-4158. - 91:(2023). [10.1016/j.mechatronics.2023.102972]

Knee prosthesis powered by a fully integrated and highly back-drivable electro-hydrostatic actuator

Tessari, Federico;Galluzzi, Renato;Tonoli, Andrea;Amati, Nicola;
2023

Abstract

In this paper, we propose the design and experimental validation of an electro-hydrostatic actuator, as an alternative to traditional actuation technologies, for a powered knee prosthesis. The aim is to demonstrate that the adopted system-level design yields a highly integrated, lightweight, back-drivable device able to satisfy the biomechanical torque and speed requirements of the knee. Moreover, the back-drivable nature of the actuators allows for active and regenerative operations in the four quadrants of the torque-speed plane. In the context of knee biomechanics, this could lead to a potential advantage with respect to other powered prosthetic solutions, in terms of power consumption and device autonomy. Different control strategies, such as position, admittance and regenerative braking controllers, are implemented and tested on a dedicated rig to validate the design choices and demonstrate the prosthesis functionality and performance.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2997762
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo