Melanoma is a malignant cancer type which develops when DNA damage occurs (mainly due to environmental factors such as ultraviolet rays). Often, melanoma results in intense and aggressive cell growth that, if not caught in time, can bring one toward death. Thus, early identification at the initial stage is fundamental to stopping the spread of cancer. In this paper, a ViT-based architecture able to classify melanoma versus non-cancerous lesions is presented. The proposed predictive model is trained and tested on public skin cancer data from the ISIC challenge, and the obtained results are highly promising. Different classifier configurations are considered and analyzed in order to find the most discriminating one. The best one reached an accuracy of 0.948, sensitivity of 0.928, specificity of 0.967, and AUROC of 0.948.
Transformer-based approach to melanoma detection / Cirrincione, Giansalvo; Cannata, Sergio; Cicceri, Giovanni; Prinzi, Francesco; Currieri, Tiziana; Lovino, Marta; Militello, Carmelo; Pasero, EROS GIAN ALESSANDRO; Vitabile, Salvatore. - In: SENSORS. - ISSN 1424-8220. - ELETTRONICO. - 23:12(2023). [10.3390/s23125677]
Transformer-based approach to melanoma detection
Giansalvo Cirrincione;Sergio Cannata;Marta Lovino;Eros Pasero;Salvatore Vitabile
2023
Abstract
Melanoma is a malignant cancer type which develops when DNA damage occurs (mainly due to environmental factors such as ultraviolet rays). Often, melanoma results in intense and aggressive cell growth that, if not caught in time, can bring one toward death. Thus, early identification at the initial stage is fundamental to stopping the spread of cancer. In this paper, a ViT-based architecture able to classify melanoma versus non-cancerous lesions is presented. The proposed predictive model is trained and tested on public skin cancer data from the ISIC challenge, and the obtained results are highly promising. Different classifier configurations are considered and analyzed in order to find the most discriminating one. The best one reached an accuracy of 0.948, sensitivity of 0.928, specificity of 0.967, and AUROC of 0.948.| File | Dimensione | Formato | |
|---|---|---|---|
| sensors-23-05677-v2.pdf accesso aperto 
											Tipologia:
											2a Post-print versione editoriale / Version of Record
										 
											Licenza:
											
											
												Creative commons
												
												
													
													
													
												
												
											
										 
										Dimensione
										784.76 kB
									 
										Formato
										Adobe PDF
									 | 784.76 kB | Adobe PDF | Visualizza/Apri | 
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2979433
			
		
	
	
	
			      	