In this article, we investigate the reliability of Google’s coral tensor processing units (TPUs) to both high-energy atmospheric neutrons (at ChipIR) and thermal neutrons from a pulsed source [at equipment materials and mechanics analyzer (EMMA)] and from a reactor [at Thermal and Epithermal Neutron Irradiation Station (TENIS)]. We report data obtained with an overall fluence of 3.41×1012n/cm2 for atmospheric neutrons (equivalent to more than 30 million years of natural irradiation) and of 7.55×1012n/cm2 for thermal neutrons. We evaluate the behavior of TPUs executing elementary operations with increasing input sizes (standard convolutions or depthwise convolutions) as well as eight convolutional neural networks (CNNs) configurations (single-shot multibox detection (SSD) MobileNet v2 and SSD MobileDet, trained with COCO dataset, and Inception v4 and ResNet-50, with ILSVRC2012 dataset). We found that, despite the high error rate, most neutron-induced errors only slightly modify the convolution output and do not change the detection or classification of CNNs. By reporting details about the error model, we provide valuable information on how to design the CNNs to avoid neutron-induced events to lead to misdetections or classifications.

High Energy and Thermal Neutrons Sensitivity of Google Tensor Processing Units / Luiz Rech Junior, Rubens; Malde, Sujit; Cazzaniga, Carlo; Kastriotou, Maria; Letiche, Manon; Frost, Christopher; Rech, Paolo. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - 69:3(2022), pp. 567-575. [10.1109/TNS.2022.3142092]

High Energy and Thermal Neutrons Sensitivity of Google Tensor Processing Units

Rech, Paolo
2022

Abstract

In this article, we investigate the reliability of Google’s coral tensor processing units (TPUs) to both high-energy atmospheric neutrons (at ChipIR) and thermal neutrons from a pulsed source [at equipment materials and mechanics analyzer (EMMA)] and from a reactor [at Thermal and Epithermal Neutron Irradiation Station (TENIS)]. We report data obtained with an overall fluence of 3.41×1012n/cm2 for atmospheric neutrons (equivalent to more than 30 million years of natural irradiation) and of 7.55×1012n/cm2 for thermal neutrons. We evaluate the behavior of TPUs executing elementary operations with increasing input sizes (standard convolutions or depthwise convolutions) as well as eight convolutional neural networks (CNNs) configurations (single-shot multibox detection (SSD) MobileNet v2 and SSD MobileDet, trained with COCO dataset, and Inception v4 and ResNet-50, with ILSVRC2012 dataset). We found that, despite the high error rate, most neutron-induced errors only slightly modify the convolution output and do not change the detection or classification of CNNs. By reporting details about the error model, we provide valuable information on how to design the CNNs to avoid neutron-induced events to lead to misdetections or classifications.
File in questo prodotto:
File Dimensione Formato  
bare_conf.pdf

accesso aperto

Descrizione: articolo principale
Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 1.72 MB
Formato Adobe PDF
1.72 MB Adobe PDF Visualizza/Apri
High_Energy_and_Thermal_Neutron_Sensitivity_of_Google_Tensor_Processing_Units.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 1.49 MB
Formato Adobe PDF
1.49 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2948484