Commercial PhotoVoltaic (PV) modules generally consist of a number of PV cells ranging between 60 and 96. The solar cells in a PV module are connected in series and partitioned in 3 or 4 strings, each protected by a bypass diode. In general, the terminals of each string are available by opening the junction box but, in case of partial shading, the current-voltage (I-V) curves of a single defective solar cell cannot be directly measured and only the I-V curve of the PV string can be obtained by experimental tests. In the present work, a novel indirect procedure to extract the parameters of shaded PV cells using models generally adjusted for irradiated cells is proposed. It is defined "One Module (or One String), Two Tests"and it requires two tests performed as close as possible: in the first step, all the Ns cells of a PV module or a string are irradiated while, in the second step, the PV module or string have a shaded cell and Ns-1 irradiated cells. In the present work, the procedure is applied to a string of a p-Si module consisting of 20 solar cells.

A novel procedure to adjust the equivalent circuit parameters of photovoltaic modules under shading / Ciocia, A.; Di Leo, P.; Fichera, S.; Giordano, F.; Malgaroli, G.; Spertino, F.. - ELETTRONICO. - (2020), pp. 711-715. (Intervento presentato al convegno 2020 International Symposium on Power Electronics, Electrical Drives, Automation and Motion, SPEEDAM 2020 tenutosi a ita nel 2020) [10.1109/SPEEDAM48782.2020.9161878].

A novel procedure to adjust the equivalent circuit parameters of photovoltaic modules under shading

Ciocia A.;Di Leo P.;Fichera S.;Giordano F.;Malgaroli G.;Spertino F.
2020

Abstract

Commercial PhotoVoltaic (PV) modules generally consist of a number of PV cells ranging between 60 and 96. The solar cells in a PV module are connected in series and partitioned in 3 or 4 strings, each protected by a bypass diode. In general, the terminals of each string are available by opening the junction box but, in case of partial shading, the current-voltage (I-V) curves of a single defective solar cell cannot be directly measured and only the I-V curve of the PV string can be obtained by experimental tests. In the present work, a novel indirect procedure to extract the parameters of shaded PV cells using models generally adjusted for irradiated cells is proposed. It is defined "One Module (or One String), Two Tests"and it requires two tests performed as close as possible: in the first step, all the Ns cells of a PV module or a string are irradiated while, in the second step, the PV module or string have a shaded cell and Ns-1 irradiated cells. In the present work, the procedure is applied to a string of a p-Si module consisting of 20 solar cells.
2020
978-1-7281-7019-0
File in questo prodotto:
File Dimensione Formato  
Post_non_editoriale.pdf

accesso aperto

Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: Pubblico - Tutti i diritti riservati
Dimensione 654.13 kB
Formato Adobe PDF
654.13 kB Adobe PDF Visualizza/Apri
Post_editoriale.pdf

accesso riservato

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 227.64 kB
Formato Adobe PDF
227.64 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2850713