Commercial PhotoVoltaic (PV) modules generally consist of a number of PV cells ranging between 60 and 96. The solar cells in a PV module are connected in series and partitioned in 3 or 4 strings, each protected by a bypass diode. In general, the terminals of each string are available by opening the junction box but, in case of partial shading, the current-voltage (I-V) curves of a single defective solar cell cannot be directly measured and only the I-V curve of the PV string can be obtained by experimental tests. In the present work, a novel indirect procedure to extract the parameters of shaded PV cells using models generally adjusted for irradiated cells is proposed. It is defined "One Module (or One String), Two Tests"and it requires two tests performed as close as possible: in the first step, all the Ns cells of a PV module or a string are irradiated while, in the second step, the PV module or string have a shaded cell and Ns-1 irradiated cells. In the present work, the procedure is applied to a string of a p-Si module consisting of 20 solar cells.
A novel procedure to adjust the equivalent circuit parameters of photovoltaic modules under shading / Ciocia, A.; Di Leo, P.; Fichera, S.; Giordano, F.; Malgaroli, G.; Spertino, F.. - ELETTRONICO. - (2020), pp. 711-715. (Intervento presentato al convegno 2020 International Symposium on Power Electronics, Electrical Drives, Automation and Motion, SPEEDAM 2020 tenutosi a ita nel 2020) [10.1109/SPEEDAM48782.2020.9161878].
A novel procedure to adjust the equivalent circuit parameters of photovoltaic modules under shading
Ciocia A.;Di Leo P.;Fichera S.;Giordano F.;Malgaroli G.;Spertino F.
2020
Abstract
Commercial PhotoVoltaic (PV) modules generally consist of a number of PV cells ranging between 60 and 96. The solar cells in a PV module are connected in series and partitioned in 3 or 4 strings, each protected by a bypass diode. In general, the terminals of each string are available by opening the junction box but, in case of partial shading, the current-voltage (I-V) curves of a single defective solar cell cannot be directly measured and only the I-V curve of the PV string can be obtained by experimental tests. In the present work, a novel indirect procedure to extract the parameters of shaded PV cells using models generally adjusted for irradiated cells is proposed. It is defined "One Module (or One String), Two Tests"and it requires two tests performed as close as possible: in the first step, all the Ns cells of a PV module or a string are irradiated while, in the second step, the PV module or string have a shaded cell and Ns-1 irradiated cells. In the present work, the procedure is applied to a string of a p-Si module consisting of 20 solar cells.File | Dimensione | Formato | |
---|---|---|---|
Post_non_editoriale.pdf
accesso aperto
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
654.13 kB
Formato
Adobe PDF
|
654.13 kB | Adobe PDF | Visualizza/Apri |
Post_editoriale.pdf
accesso riservato
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
227.64 kB
Formato
Adobe PDF
|
227.64 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2850713