We present a new method for electrochemical sensing, which compensates the fouling effect of propofol through machine learning (ML) model. Direct and continuous monitoring of propofol is crucial in the development of automatic systems for control of drug infusion in anaesthesiology. The fouling effect on electrodes discourages the possibility of continuous online monitoring of propofol since polymerization of the surface produces sensor drift. Several approaches have been proposed to limit the phenomenon at the biochemical interface; instead, here, we present a novel ML-based calibration procedure. In this paper, we analyze a dataset of 600 samples acquired through staircase cyclic voltammetry (SCV), resembling the scenario of continuous monitoring of propofol, both in PBS and in undiluted human serum, to demonstrate that ML-based model solves electrode fouling of anaesthetics. The proposed calibration approach is based on Gaussian radial basis function support vector classifier (RBF-SVC) that achieves classification accuracy of 98.9 % in PBS, and 100 % in undiluted human serum. The results prove the ability of the ML-based model to correctly classify propofol concentration in the therapeutic range between 1 µM and 60 µM with levels of 10 µM, continuously up to ten minutes, with one sample every 30 s.
Continuous monitoring of propofol in human serum with fouling compensation by support vector classifier / Aiassa, Simone; Ny Hanitra, Ivan; Sandri, Gabriele; Totu, Tiberiu; Grassi, Francesco; Criscuolo, Francesca; De Micheli, Giovanni; Carrara, Sandro; Demarchi, Danilo. - In: BIOSENSORS & BIOELECTRONICS. - ISSN 0956-5663. - 171:(2021), p. 112666. [10.1016/j.bios.2020.112666]
Continuous monitoring of propofol in human serum with fouling compensation by support vector classifier
Simone Aiassa;Sandro Carrara;Danilo Demarchi
2021
Abstract
We present a new method for electrochemical sensing, which compensates the fouling effect of propofol through machine learning (ML) model. Direct and continuous monitoring of propofol is crucial in the development of automatic systems for control of drug infusion in anaesthesiology. The fouling effect on electrodes discourages the possibility of continuous online monitoring of propofol since polymerization of the surface produces sensor drift. Several approaches have been proposed to limit the phenomenon at the biochemical interface; instead, here, we present a novel ML-based calibration procedure. In this paper, we analyze a dataset of 600 samples acquired through staircase cyclic voltammetry (SCV), resembling the scenario of continuous monitoring of propofol, both in PBS and in undiluted human serum, to demonstrate that ML-based model solves electrode fouling of anaesthetics. The proposed calibration approach is based on Gaussian radial basis function support vector classifier (RBF-SVC) that achieves classification accuracy of 98.9 % in PBS, and 100 % in undiluted human serum. The results prove the ability of the ML-based model to correctly classify propofol concentration in the therapeutic range between 1 µM and 60 µM with levels of 10 µM, continuously up to ten minutes, with one sample every 30 s.File | Dimensione | Formato | |
---|---|---|---|
BiosensorsandBioelectronics2021(preprint).pdf
Open Access dal 16/10/2022
Descrizione: Articolo principale post-print
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
PUBBLICO - Tutti i diritti riservati
Dimensione
1.22 MB
Formato
Adobe PDF
|
1.22 MB | Adobe PDF | Visualizza/Apri |
BiosensorsandBioelectronics2021.pdf
non disponibili
Descrizione: Articolo principale post-print Versione Editoriale
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
810.34 kB
Formato
Adobe PDF
|
810.34 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2846959