Lean NOx Trap (LNT) is one of the most eective after-treatment technologies used to reduce NOx emissions of diesel engines. One relevant problem in this context is LNT regeneration timing control. This problem is indeed difficult due to the fact that LNTs are highly nonlinear systems, involving complex physical/chemical processes that are hard to model. In this paper, a novel data-driven model predictive control (D2-MPC) approach for regeneration timing of LNTs is proposed, allowing us to overcome these issues. This approach does not require a physical model of the engine/trap system but is based on low-complexity polynomial prediction model, directly identied from data. The regeneration timing is computed through an optimization algorithm, which uses the identied model to predict the LNT behavior. The proposed D2- MPC approach is tested in a co-simulation study, where the plant is represented by a detailed LNT model, developed using the well-known commercial tool AMEsim, and the controller is implemented in Matlab/Simulink.
Data-driven Model Predictive Control for Lean NOx Trap Regeneration / Karimshoushtari, Milad; Novara, Carlo; Trotta, Antonino. - (2017), pp. 6178-6183. (Intervento presentato al convegno 20th IFAC World Congress tenutosi a Toulouse, France).
Data-driven Model Predictive Control for Lean NOx Trap Regeneration
KARIMSHOUSHTARI, MILAD;NOVARA, Carlo;TROTTA, ANTONINO
2017
Abstract
Lean NOx Trap (LNT) is one of the most eective after-treatment technologies used to reduce NOx emissions of diesel engines. One relevant problem in this context is LNT regeneration timing control. This problem is indeed difficult due to the fact that LNTs are highly nonlinear systems, involving complex physical/chemical processes that are hard to model. In this paper, a novel data-driven model predictive control (D2-MPC) approach for regeneration timing of LNTs is proposed, allowing us to overcome these issues. This approach does not require a physical model of the engine/trap system but is based on low-complexity polynomial prediction model, directly identied from data. The regeneration timing is computed through an optimization algorithm, which uses the identied model to predict the LNT behavior. The proposed D2- MPC approach is tested in a co-simulation study, where the plant is represented by a detailed LNT model, developed using the well-known commercial tool AMEsim, and the controller is implemented in Matlab/Simulink.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2677291
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo