Low power adsorption chillers with low desorption temperatures deserve particular attention, because of the possibility of driving them with a solar thermal system integrated with buildings. The monitoring of a recent solar cooling installation in Turin, Italy, has pointed out the opportunity of developing a dynamic mathematical model, in order to simulate the transient performances of this plant. Focusing on the aforementioned low power-low temperature adsorption chiller category, this work proposes a numerical model of the systems, that include a novel zeolite as the adsorbent and water as the refrigerant fluid. The simulation results have been verified by means of the nominal values of one of the very few commercial chillers of this typology available on the market, and have compared with experimental data found in the literature for similar plants.
Thermodynamic modelling of an adsorption chiller based on a zeolite / Badami, Marco; Portoraro, Armando; Simonetti, Marco; Tebaldi, Paolo. - 6B : Energy:(2015). (Intervento presentato al convegno ASME 2015 International Mechanical Engineering Congress and Exposition, IMECE 2015 tenutosi a Houston, Texas, USA nel November 13–19, 2015) [10.1115/IMECE201550521].
Thermodynamic modelling of an adsorption chiller based on a zeolite
BADAMI, Marco;PORTORARO, ARMANDO;SIMONETTI, MARCO;TEBALDI, PAOLO
2015
Abstract
Low power adsorption chillers with low desorption temperatures deserve particular attention, because of the possibility of driving them with a solar thermal system integrated with buildings. The monitoring of a recent solar cooling installation in Turin, Italy, has pointed out the opportunity of developing a dynamic mathematical model, in order to simulate the transient performances of this plant. Focusing on the aforementioned low power-low temperature adsorption chiller category, this work proposes a numerical model of the systems, that include a novel zeolite as the adsorbent and water as the refrigerant fluid. The simulation results have been verified by means of the nominal values of one of the very few commercial chillers of this typology available on the market, and have compared with experimental data found in the literature for similar plants.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2673455
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo