To design retrofit and/or conservation of existing reinforced concrete structures, the assessment of concrete strength is generally required. The current methodologies consist of Destructive Tests (DT), based on uniaxial compression tests performed on concrete cores extracted from a structure, and/or Non-Destructive Tests (NDT), in which the strength of concrete is indirectly estimated by measur- ing other physical properties (like the ultrasonic pulse velocity). Nevertheless, in several situations (like, e.g., the seismic vulnerability assessment of long-term service infrastructures), the traditional DT and NDT cannot be used. Hence, a new simplified approach is described in this paper. It can be applied to infrastructures located in a precise geographical area, where the average strength of concrete (and the rela- tive percentiles) is a function of the year of construction. Such relationship is summarized by the so-called “strength curves”, statistically computed from a huge database stored in the Department of Structural and Geotechnical Engineering of Politecnico di Torino (Italy). Referring to a concrete dam and stadium built during the 1950s and 1960s in Aosta and in Turin area, respectively, the strength predicted by these curves is in good agreements with the measurements of DT.

The assessment of concrete strength of existing Italian infrastructures / Fantilli, ALESSANDRO PASQUALE; Frigo, Barbara; Chiaia, Bernardino. - ELETTRONICO. - (2016), pp. 1976-1981. (Intervento presentato al convegno 6th International Conference on Structural Engineering, Mechanics and Computation, SEMC 2016 tenutosi a Cape Town, South Africa. nel 2016).

The assessment of concrete strength of existing Italian infrastructures

FANTILLI, ALESSANDRO PASQUALE;FRIGO, BARBARA;CHIAIA, Bernardino
2016

Abstract

To design retrofit and/or conservation of existing reinforced concrete structures, the assessment of concrete strength is generally required. The current methodologies consist of Destructive Tests (DT), based on uniaxial compression tests performed on concrete cores extracted from a structure, and/or Non-Destructive Tests (NDT), in which the strength of concrete is indirectly estimated by measur- ing other physical properties (like the ultrasonic pulse velocity). Nevertheless, in several situations (like, e.g., the seismic vulnerability assessment of long-term service infrastructures), the traditional DT and NDT cannot be used. Hence, a new simplified approach is described in this paper. It can be applied to infrastructures located in a precise geographical area, where the average strength of concrete (and the rela- tive percentiles) is a function of the year of construction. Such relationship is summarized by the so-called “strength curves”, statistically computed from a huge database stored in the Department of Structural and Geotechnical Engineering of Politecnico di Torino (Italy). Referring to a concrete dam and stadium built during the 1950s and 1960s in Aosta and in Turin area, respectively, the strength predicted by these curves is in good agreements with the measurements of DT.
2016
9781138029279
9781138029279
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2666256
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo