Heat pumps are expected to play a major role in future energy scenarios. Proliferation of these systems in urban areas may cause issues related to environmental impact on water basins and interactions between installations. Both issues are associated with the thermal plume produced by the heat pump during operation and are particularly evident in the case of groundwater flow, because of the advective term of heat transfer. In this paper, the impact of heat pump installations is calculated through a thermo-fluid dynamic model of the subsurface which considers fluid flow in the saturated unit and heat transfer both in the saturated and unsaturated units. This model is coupled with the thermal request of the user and the heat pump performances through appropriate boundary conditions imposed at the wells. Various scenarios corresponding to different annual heating/cooling request, groundwater velocity, groundwater temperature variation are considered.

Energy and environmental impact of groundwater heat pumps in urban areas / Verda, Vittorio; Sciacovelli, Adriano; LO RUSSO, Stefano; Taddia, Glenda. - ELETTRONICO. - 6:(2012), pp. 571-579. (Intervento presentato al convegno ASME 2012 - International Mechanical Engineering Congress and Exposition - IMECE 2012 tenutosi a Houston nel 9-15 November 2012) [10.1115/IMECE2012-87593].

Energy and environmental impact of groundwater heat pumps in urban areas.

VERDA, Vittorio;SCIACOVELLI, ADRIANO;LO RUSSO, STEFANO;TADDIA, GLENDA
2012

Abstract

Heat pumps are expected to play a major role in future energy scenarios. Proliferation of these systems in urban areas may cause issues related to environmental impact on water basins and interactions between installations. Both issues are associated with the thermal plume produced by the heat pump during operation and are particularly evident in the case of groundwater flow, because of the advective term of heat transfer. In this paper, the impact of heat pump installations is calculated through a thermo-fluid dynamic model of the subsurface which considers fluid flow in the saturated unit and heat transfer both in the saturated and unsaturated units. This model is coupled with the thermal request of the user and the heat pump performances through appropriate boundary conditions imposed at the wells. Various scenarios corresponding to different annual heating/cooling request, groundwater velocity, groundwater temperature variation are considered.
2012
9780791845226
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2569737
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo