Hand fatigue is one of the major problems of astronauts during Extravehicular Activity (EVA), due to the stiffness of the space suit, in particular of the glove. In order to evaluate the stiffness of EVA gloves, different methods have been proposed in the past, mainly focused on the effects of wearing an EVA glove on hand performance when executing test protocols. In this paper, an objective method for the evaluation of the stiffness of EVA gloves is proposed, by means of a tendon-actuated finger probe. The finger probe is equipped with accelerometers, to measure the angles of its phalanges. These are actuated by applying different torques using the finger probe tendons. The EVA glove is tested in both pressurized and non pressurized conditions, thanks to a hypobaric glove box. An Orlan-DM EVA glove is tested and stiffness results are presented. This setup can be used for different kinds of gloves, not necessarily for EVA application, and allows direct, numerical measurement of their stiffness.

Stiffness of an EVA glove: objective evaluation and testing procedures / SEYED MOUSAVI, MOHAMAD MEHDI; Appendino, Silvia; Battezzato, Alessandro; CHEN CHEN, Fai; Favetto, Alain; Pescarmona, Francesco. - ELETTRONICO. - (2013). (Intervento presentato al convegno 12th Symposium on Advanced Space Technologies in Robotics and Automation ASTRA 2013 tenutosi a Noordwijk, The nederland nel May 15 – 17 2013).

Stiffness of an EVA glove: objective evaluation and testing procedures

SEYED MOUSAVI, MOHAMAD MEHDI;APPENDINO, Silvia;BATTEZZATO, ALESSANDRO;CHEN CHEN, FAI;FAVETTO, ALAIN;PESCARMONA, FRANCESCO
2013

Abstract

Hand fatigue is one of the major problems of astronauts during Extravehicular Activity (EVA), due to the stiffness of the space suit, in particular of the glove. In order to evaluate the stiffness of EVA gloves, different methods have been proposed in the past, mainly focused on the effects of wearing an EVA glove on hand performance when executing test protocols. In this paper, an objective method for the evaluation of the stiffness of EVA gloves is proposed, by means of a tendon-actuated finger probe. The finger probe is equipped with accelerometers, to measure the angles of its phalanges. These are actuated by applying different torques using the finger probe tendons. The EVA glove is tested in both pressurized and non pressurized conditions, thanks to a hypobaric glove box. An Orlan-DM EVA glove is tested and stiffness results are presented. This setup can be used for different kinds of gloves, not necessarily for EVA application, and allows direct, numerical measurement of their stiffness.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2519066
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo