In this paper a preliminary study concerning the possibility of managing data from an early warning network to drive a semi-active control system has been carried out. In particular, by evaluating the frequency content of the seismic input, by means of Fast Fourier Transform, at the accelerometric stations, it is possible to characterize the energy content of the incoming earthquake and thus modify the mechanical properties of a SDOF structure in order to improve its seismic performance. In particular, the semi-active algorithm, to control the systems’ mechanical parameters, is based on the minimisation of a suitable index representing the seismic frequency response of the system in terms of both relative displacement and absolute acceleration. Effectiveness of the proposed control strategy has been tested by varying the anticipation time value and by considering a wide set of recorded seismic inputs having very different dynamic features. Moreover, the results obtained are compared with the performance to be achieved by using a standard semiactive control algorithm proving the efficiency of the proposed approach.
SEMI-ACTIVE CONTROL OF STRUCTURES BY USING EARLY WARNING SEISMIC NETWORK INFORMATION / Petti, L., De Iuliis, M., Palazzo, B.. - (2008). (4th European Conference on Structural Control (4ECSC) San Petersburg 8-12 September 2008).
SEMI-ACTIVE CONTROL OF STRUCTURES BY USING EARLY WARNING SEISMIC NETWORK INFORMATION
De Iuliis, Massimiliano;Palazzo, Bruno
2008
Abstract
In this paper a preliminary study concerning the possibility of managing data from an early warning network to drive a semi-active control system has been carried out. In particular, by evaluating the frequency content of the seismic input, by means of Fast Fourier Transform, at the accelerometric stations, it is possible to characterize the energy content of the incoming earthquake and thus modify the mechanical properties of a SDOF structure in order to improve its seismic performance. In particular, the semi-active algorithm, to control the systems’ mechanical parameters, is based on the minimisation of a suitable index representing the seismic frequency response of the system in terms of both relative displacement and absolute acceleration. Effectiveness of the proposed control strategy has been tested by varying the anticipation time value and by considering a wide set of recorded seismic inputs having very different dynamic features. Moreover, the results obtained are compared with the performance to be achieved by using a standard semiactive control algorithm proving the efficiency of the proposed approach.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/3018076
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo