Base isolation has been widely considered as an effective strategy to protect structures subject to seismic excitations. However, it has been shown that, in the case of seismic excitations with high energy content at low frequencies, i.e. a near-fault event or a seismic wave propagating itself through alluvial soil, isolation bearings may undergo gross deformations. By increasing the isolation layer damping, base displacements can be reduced. However, high damping in the isolation layer affects unfavourably the behaviour of the superstructure due to spill-over effects. Observing that the response of base-isolated (BI) systems is dominated by the first-modal contribution and that Tuned Mass Damping (TMD) is able to reduce the fundamental vibration mode, a new idea of combining both properties into a unique system (BI&TMD) was proposed and investigated by Palazzo and Petti in 1994. In this paper, a numerical investigation of BI&TMD combined control strategy applied to a base-isolated benchmark structure is presented. The benchmark base-isolated building model has been developed by Nagarajaiah and Narasimhan (2004), to investigate the performance of various passive, semi-active and active control methodologies. The aim is to test, in a comparable way, the effectiveness of the BI&TMD passive strategy by evaluating several seismic performance indexes under selected seismic excitations. Design criteria of the mass damping control system based on the transfer function norm relating the seismic input to the isolators drift are carried out. Results show a mean reduction in the seismic response, for all seismic inputs, of 30% in terms of base displacements, and of 10% of superstructure absolute accelerations thus highlighting the efficiency of the proposed strategy.
TUNED MASS DAMPERS TO CONTROL THE BASE-ISOLATED BENCHMARK BUILDING MODEL / Palazzo, B., Petti, L., De Iuliis, M.. - (2006). (First European Conference on Earthquake Engineering and Seismology (1st ECEES) Geneva 3-8 September 2006).
TUNED MASS DAMPERS TO CONTROL THE BASE-ISOLATED BENCHMARK BUILDING MODEL
Palazzo, Bruno;De Iuliis, Massimiliano
2006
Abstract
Base isolation has been widely considered as an effective strategy to protect structures subject to seismic excitations. However, it has been shown that, in the case of seismic excitations with high energy content at low frequencies, i.e. a near-fault event or a seismic wave propagating itself through alluvial soil, isolation bearings may undergo gross deformations. By increasing the isolation layer damping, base displacements can be reduced. However, high damping in the isolation layer affects unfavourably the behaviour of the superstructure due to spill-over effects. Observing that the response of base-isolated (BI) systems is dominated by the first-modal contribution and that Tuned Mass Damping (TMD) is able to reduce the fundamental vibration mode, a new idea of combining both properties into a unique system (BI&TMD) was proposed and investigated by Palazzo and Petti in 1994. In this paper, a numerical investigation of BI&TMD combined control strategy applied to a base-isolated benchmark structure is presented. The benchmark base-isolated building model has been developed by Nagarajaiah and Narasimhan (2004), to investigate the performance of various passive, semi-active and active control methodologies. The aim is to test, in a comparable way, the effectiveness of the BI&TMD passive strategy by evaluating several seismic performance indexes under selected seismic excitations. Design criteria of the mass damping control system based on the transfer function norm relating the seismic input to the isolators drift are carried out. Results show a mean reduction in the seismic response, for all seismic inputs, of 30% in terms of base displacements, and of 10% of superstructure absolute accelerations thus highlighting the efficiency of the proposed strategy.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/3018068
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo