This paper examines the performance of a novel geotechnical seismic isolation system using experimental shake table excitations. The objective of the system is to protect new and existing multi-story buildings from seismic loads. The isolation system benefits from the soil-structure interaction mechanism using lightweight expanded clay aggregates. These rotary-kiln-manufactured aggregates improve the damping performance of the system without degradation due to physical, chemical, or environmental conditions. The testing specimen included a reduced-scale multi-story building supported by a pile system and surrounded by isolating walls. A laminar box transferred the dynamic motion of the shake table to the pile-structure system. Dynamic loads included earthquake records from significant incidents and harmonic loads simulating ascending amplitudes or frequencies. All dynamic loads had adequate scaling to preserve the frequency content and acceleration intensities. Results involved time-history responses, including acceleration, velocity, displacement, and drift, plus response spectra to obtain damping ratios. Data analysis revealed that the proposed geotechnical seismic isolation can significantly reduce the seismic effect, including drift due to the shifting period and improved damping.

Shake Table Studies of a Geotechnical Seismic Isolation System Using Lightweight Aggregates / Naseri, F., Dehkordi, F.M., Tehrani, F.M.. - 2025-:(2025), pp. 130-138. (Geo-Extreme 2025: Civil Infrastructure, Geomaterials, and Case Histories usa 2025) [10.1061/9780784486511.014].

Shake Table Studies of a Geotechnical Seismic Isolation System Using Lightweight Aggregates

Naseri, Farzad;Dehkordi, Farmehr M.;
2025

Abstract

This paper examines the performance of a novel geotechnical seismic isolation system using experimental shake table excitations. The objective of the system is to protect new and existing multi-story buildings from seismic loads. The isolation system benefits from the soil-structure interaction mechanism using lightweight expanded clay aggregates. These rotary-kiln-manufactured aggregates improve the damping performance of the system without degradation due to physical, chemical, or environmental conditions. The testing specimen included a reduced-scale multi-story building supported by a pile system and surrounded by isolating walls. A laminar box transferred the dynamic motion of the shake table to the pile-structure system. Dynamic loads included earthquake records from significant incidents and harmonic loads simulating ascending amplitudes or frequencies. All dynamic loads had adequate scaling to preserve the frequency content and acceleration intensities. Results involved time-history responses, including acceleration, velocity, displacement, and drift, plus response spectra to obtain damping ratios. Data analysis revealed that the proposed geotechnical seismic isolation can significantly reduce the seismic effect, including drift due to the shifting period and improved damping.
2025
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/3018060
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo