Extreme heat concurrently increases temperature-sensitive demand, reduces generation efficiency, and derates line capacity and transformer loadability, placing multi-energy complementary systems (MECS) under heightened operational stress. This paper develops a heat-aware resilient scheduling framework that incorporates temperature-driven load growth, photovoltaic and thermal efficiency degradation, and line/transformer capacity derating into the dispatch model; couples a vulnerability-weighted graded load-shedding scheme guided by node power-flow betweenness with incentive-based demand response to protect critical nodes and essential loads; and evaluates system resilience using a Combined Analytic Hierarchy Process–Entropy Resilience Evaluation (CAHP–ERE) method. On a modified IEEE 30-bus test system with 96 intraday intervals, enabling demand response in Scenario 5 reduces direct load shedding from 1059 MWh to 559 MWh and increases the resilience index from 0.20 to 0.43 relative to Scenario 4, indicating improved operational security under concurrent extreme heat and power shortage.

Resilience-oriented scheduling and evaluation of multi-energy complementary systems under extreme heat / Tang, L., Han, Y., Yan, C., Wang, C., Huang, T.. - In: ELECTRIC POWER SYSTEMS RESEARCH. - ISSN 0378-7796. - ELETTRONICO. - 258:(2026). [10.1016/j.epsr.2026.113171]

Resilience-oriented scheduling and evaluation of multi-energy complementary systems under extreme heat

Huang T.
2026

Abstract

Extreme heat concurrently increases temperature-sensitive demand, reduces generation efficiency, and derates line capacity and transformer loadability, placing multi-energy complementary systems (MECS) under heightened operational stress. This paper develops a heat-aware resilient scheduling framework that incorporates temperature-driven load growth, photovoltaic and thermal efficiency degradation, and line/transformer capacity derating into the dispatch model; couples a vulnerability-weighted graded load-shedding scheme guided by node power-flow betweenness with incentive-based demand response to protect critical nodes and essential loads; and evaluates system resilience using a Combined Analytic Hierarchy Process–Entropy Resilience Evaluation (CAHP–ERE) method. On a modified IEEE 30-bus test system with 96 intraday intervals, enabling demand response in Scenario 5 reduces direct load shedding from 1059 MWh to 559 MWh and increases the resilience index from 0.20 to 0.43 relative to Scenario 4, indicating improved operational security under concurrent extreme heat and power shortage.
File in questo prodotto:
File Dimensione Formato  
Resilience-oriented scheduling and evaluation of multi-energy complementary systems under extreme heat.pdf

accesso riservato

Descrizione: Version of Record
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 6.85 MB
Formato Adobe PDF
6.85 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
main.pdf

embargo fino al 25/04/2028

Descrizione: AAM
Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: Creative commons
Dimensione 6.29 MB
Formato Adobe PDF
6.29 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/3017535