Within the context of the ESA-funded PARSEC activity, this work investigates the use of plasma actuators to control flow separation in over-expanded rocket nozzles. A parametric two-dimensional numerical study is conducted in preparation for a forthcoming subscale cold-flow experiment at Technische Universitaet Dresden. RANS simulations are performed using an in-house finite-volume solver, modeling the quasi-DC plasma actuator as a localized volumetric heat source. The actuator location and input power are varied to qualitatively assess their influence on the nozzle flow field under steady over-expanded conditions at a fixed nozzle pressure ratio. An additional high-temperature simulation performed with the Ansys Fluent software is used to verify that high-temperature effects have a limited impact on the flow behavior under the simulated conditions. The results show that plasma-induced heating can significantly modify the separation pattern and, in some cases, promote attached flow, while insufficient power provides limited control authority.
Numerical Investigation on the Use of Plasma Actuators for Separation Control in Over-Expanded Nozzles / Tozzi, D., Bach, C., Ferrero, A., Masseni, F., Pastrone, D.G.. - (2026). (AIAA Science and Technology Forum and Exposition, AIAA SciTech Forum 2026 Orlando (USA) 12-16 January 2026) [10.2514/6.2026-2742].
Numerical Investigation on the Use of Plasma Actuators for Separation Control in Over-Expanded Nozzles
Tozzi, Daniele;Bach, Christian;Ferrero, Andrea;Masseni, Filippo;Pastrone, Dario G.
2026
Abstract
Within the context of the ESA-funded PARSEC activity, this work investigates the use of plasma actuators to control flow separation in over-expanded rocket nozzles. A parametric two-dimensional numerical study is conducted in preparation for a forthcoming subscale cold-flow experiment at Technische Universitaet Dresden. RANS simulations are performed using an in-house finite-volume solver, modeling the quasi-DC plasma actuator as a localized volumetric heat source. The actuator location and input power are varied to qualitatively assess their influence on the nozzle flow field under steady over-expanded conditions at a fixed nozzle pressure ratio. An additional high-temperature simulation performed with the Ansys Fluent software is used to verify that high-temperature effects have a limited impact on the flow behavior under the simulated conditions. The results show that plasma-induced heating can significantly modify the separation pattern and, in some cases, promote attached flow, while insufficient power provides limited control authority.| File | Dimensione | Formato | |
|---|---|---|---|
|
tozzi-et-al-2026-numerical-investigation-on-the-use-of-plasma-actuators-for-separation-control-in-over-expanded-nozzles.pdf
accesso riservato
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
3.75 MB
Formato
Adobe PDF
|
3.75 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/3016821