To facilitate structural analyses, international standards, such as the fib Model Code 2020, adopt simplified constitutive bond laws, proposing an average relationship between bond stress and slip derived from extensive experimental campaigns of pull-out tests. However, pull-out tests induce stress and strain states that differ significantly from those occurring in structural elements under service conditions. Moreover, analyses in service conditions of RC members typically assume that, starting from the zero-slip section, the bond stress increases along the transmission length and reaches its maximum at the cracked section. This assumed distribution of the bond stress is not supported by the experimental evidence available in the literature for an RC tie with a length sufficient to prevent the formation of intermediate cracks. Experimental observations instead reveal decreasing bond stress distributions near the free ends, even in the presence of increasing slip, and zero bond stress at the ends. Per agevolare le analisi strutturali, le normative internazionali, come il fib Model Code 2020, adottano leggi costitutive di aderenza semplici, proponendo una relazione media basata sui risultati di un’estesa campagna sperimentale di prove di pull-out. Tuttavia, le prove di pull-out introducono stati di tensione e deformazione che differiscono sensibilmente da quelli che si instaurano negli elementi strutturali in condizioni di esercizio. D’altra parte, nelle analisi in condizioni di esercizio, partendo dalla sezione di zero-slip, si assume una distribuzione crescente della tensione di aderenza, che raggiunge il massimo in corrispondenza della sezione fessurata. Questa distribuzione della tensione di aderenza non è confermata dai dati sperimentali di letteratura riguardanti un tirante di calcestruzzo armato, con lunghezza tale da evitare la formazione di fessure intermedie. Si osservano, in prossimità delle estremità, distribuzioni decrescenti della tensione di aderenza, nonostante valori di scorrimento crescenti, e valori nulli della tensione di aderenza sulla sezione di estremità.
Legge di aderenza sperimentale in esercizio da prova su tirante in c.a / Debernardi, P.G., Taliano, M.. - ELETTRONICO. - (2026), pp. 1072-1079. (ICC Italian Concrete Conference : Costruzioni in calcestruzzo: opportunità e nuove sfide Bergamo (Ita) 24-26 giugno 2026).
Legge di aderenza sperimentale in esercizio da prova su tirante in c.a.
Pier Giorgio Debernardi;Maurizio Taliano
2026
Abstract
To facilitate structural analyses, international standards, such as the fib Model Code 2020, adopt simplified constitutive bond laws, proposing an average relationship between bond stress and slip derived from extensive experimental campaigns of pull-out tests. However, pull-out tests induce stress and strain states that differ significantly from those occurring in structural elements under service conditions. Moreover, analyses in service conditions of RC members typically assume that, starting from the zero-slip section, the bond stress increases along the transmission length and reaches its maximum at the cracked section. This assumed distribution of the bond stress is not supported by the experimental evidence available in the literature for an RC tie with a length sufficient to prevent the formation of intermediate cracks. Experimental observations instead reveal decreasing bond stress distributions near the free ends, even in the presence of increasing slip, and zero bond stress at the ends. Per agevolare le analisi strutturali, le normative internazionali, come il fib Model Code 2020, adottano leggi costitutive di aderenza semplici, proponendo una relazione media basata sui risultati di un’estesa campagna sperimentale di prove di pull-out. Tuttavia, le prove di pull-out introducono stati di tensione e deformazione che differiscono sensibilmente da quelli che si instaurano negli elementi strutturali in condizioni di esercizio. D’altra parte, nelle analisi in condizioni di esercizio, partendo dalla sezione di zero-slip, si assume una distribuzione crescente della tensione di aderenza, che raggiunge il massimo in corrispondenza della sezione fessurata. Questa distribuzione della tensione di aderenza non è confermata dai dati sperimentali di letteratura riguardanti un tirante di calcestruzzo armato, con lunghezza tale da evitare la formazione di fessure intermedie. Si osservano, in prossimità delle estremità, distribuzioni decrescenti della tensione di aderenza, nonostante valori di scorrimento crescenti, e valori nulli della tensione di aderenza sulla sezione di estremità.| File | Dimensione | Formato | |
|---|---|---|---|
|
Legge aderenza sperimentale esercizio prova tirante ca.pdf
accesso riservato
Descrizione: Articolo_Legge di aderenza sperimentale in esercizio da prova su tirante in c.a.
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
1.24 MB
Formato
Adobe PDF
|
1.24 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/3016707