This paper proposes a safety-oriented and interpretable hybrid framework for ECG denoising that decouples artifact intensity estimation from waveform restoration. Three Regression Tsetlin Machines, trained with frequency-isolated features and hard negative mining, estimate normalized intensities of baseline wander, muscle artifact, and power line interference. Calibrated estimates modulate deterministic wavelet-based attenuation and adaptive notch filtering, enabling adaptive yet bounded suppression without direct waveform reconstruction. Evaluated on 1000 windows from 10 unseen patients under realistic mixed-noise conditions, the framework achieves a mean SNR gain of +8.50 dB (95% CI: [+7.90, +9.10]) and satisfies IEC 60601-2-25 amplitude tolerances in four of five noise categories. Integer-only inference requires 56 ms per 4-second window (71× real-time), while clause-level transparency supports feature auditing and physiological validation, enabling predictable behavior and suitability for safety-critical and embedded deployment.

Safety-Oriented Interpretable ECG Denoising with Regression Tsetlin Machines / Maselli, G., Puntorieri, R., Viticchié, A., Aliberti, A.. - (2026), pp. 74-79. (2026 IEEE 39th International Symposium on Computer-Based Medical Systems (CBMS) Limassol, Cyprus 03-05 June 2026) [10.1109/cbms69103.2026.00023].

Safety-Oriented Interpretable ECG Denoising with Regression Tsetlin Machines

Puntorieri, Roberto;Aliberti, Alessandro
2026

Abstract

This paper proposes a safety-oriented and interpretable hybrid framework for ECG denoising that decouples artifact intensity estimation from waveform restoration. Three Regression Tsetlin Machines, trained with frequency-isolated features and hard negative mining, estimate normalized intensities of baseline wander, muscle artifact, and power line interference. Calibrated estimates modulate deterministic wavelet-based attenuation and adaptive notch filtering, enabling adaptive yet bounded suppression without direct waveform reconstruction. Evaluated on 1000 windows from 10 unseen patients under realistic mixed-noise conditions, the framework achieves a mean SNR gain of +8.50 dB (95% CI: [+7.90, +9.10]) and satisfies IEC 60601-2-25 amplitude tolerances in four of five noise categories. Integer-only inference requires 56 ms per 4-second window (71× real-time), while clause-level transparency supports feature auditing and physiological validation, enabling predictable behavior and suitability for safety-critical and embedded deployment.
2026
979-8-3315-4999-2
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/3016487
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo