Active EMI filters (AEFs) are an effective solution for mitigating conducted electromagnetic disturbances in highvoltage (HV) power electronic systems. After design and prototyping, experimental validation is a critical step to ensure that the AEF meets the target performance. However, for HV designs, the testing process is often complex, time-consuming, and constrained by safety requirements. This paper proposes a lowvoltage (LV) measurement setup for the validation and testing of AEFs intended for HV applications. The proposed approach reproduces disturbance levels comparable to those encountered in HV operation, while allowing the use of standard laboratory equipment and simplified safety procedures. Experimental results demonstrate that the LV setup enables reliable evaluation of AEF performance, providing a low-risk pre-validation method prior to full-scale HV testing.

A Low-Voltage Test Setup for the Characterization of High-Voltage Active EMI Filters / Serra, J., Fishta, M., Fiori, F.. - STAMPA. - (2026), pp. 1-5. (International Symposium on Electromagnetic Compatibility (EMC Europe 2026) Praga (Cze) 31 August - 4 September 2026).

A Low-Voltage Test Setup for the Characterization of High-Voltage Active EMI Filters

Serra, Jacopo;Fishta, Markeljan;Fiori, Franco
2026

Abstract

Active EMI filters (AEFs) are an effective solution for mitigating conducted electromagnetic disturbances in highvoltage (HV) power electronic systems. After design and prototyping, experimental validation is a critical step to ensure that the AEF meets the target performance. However, for HV designs, the testing process is often complex, time-consuming, and constrained by safety requirements. This paper proposes a lowvoltage (LV) measurement setup for the validation and testing of AEFs intended for HV applications. The proposed approach reproduces disturbance levels comparable to those encountered in HV operation, while allowing the use of standard laboratory equipment and simplified safety procedures. Experimental results demonstrate that the LV setup enables reliable evaluation of AEF performance, providing a low-risk pre-validation method prior to full-scale HV testing.
File in questo prodotto:
File Dimensione Formato  
2026190306.pdf

accesso aperto

Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: Pubblico - Tutti i diritti riservati
Dimensione 697.78 kB
Formato Adobe PDF
697.78 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/3012563