This study explores infrared thermography as a cost-effective alternative to computed tomography for detecting subsurface defects in parts produced by powder bed fusion with an electron beam (PBF-EB). Ti6Al4V specimens were produced with designed defects that mimic subsurface pores or discontinuities whose size and depth are typical of PBF-EB. Computed tomography (CT-scan) was used to collect information on the defect dimensions and coordinates accurately. The same samples were therefore analysed using Joule heating infrared thermography, applying electric current while an infrared camera recorded the temperature development on the surface of the sample. The joint analysis of CT scan and thermography data provided a comprehensive study on the limits of the inspection technologies, PBF-EB process, and measuring system in terms of defect size, depth, and the size-to-depth ratio. The results showed that the surface characteristics of the PBF-EB are critical for thermography.
Detection of sub-superficial defects by infrared thermography in parts made by powder bed fusion with electron beam / Defanti, Silvio; De Giorgi, Simone; Rizza, Giovanni; Colombini, Giulia; Tognoli, Emanuele; Ayberk Gürbüz, Ahmet; Denti, Lucia; Galati, Manuela; Iuliano, Luca. - ELETTRONICO. - 57:(2025), pp. 38-46. (Intervento presentato al convegno 17th Italian Manufacturing Association Conference, AITeM 2025 tenutosi a Bari (Italia) nel 10 September 2025 - 12 September 2025) [10.21741/9781644903735-5].
Detection of sub-superficial defects by infrared thermography in parts made by powder bed fusion with electron beam
Simone DE GIORGI;Giovanni RIZZA;Manuela Galati;Luca Iuliano
2025
Abstract
This study explores infrared thermography as a cost-effective alternative to computed tomography for detecting subsurface defects in parts produced by powder bed fusion with an electron beam (PBF-EB). Ti6Al4V specimens were produced with designed defects that mimic subsurface pores or discontinuities whose size and depth are typical of PBF-EB. Computed tomography (CT-scan) was used to collect information on the defect dimensions and coordinates accurately. The same samples were therefore analysed using Joule heating infrared thermography, applying electric current while an infrared camera recorded the temperature development on the surface of the sample. The joint analysis of CT scan and thermography data provided a comprehensive study on the limits of the inspection technologies, PBF-EB process, and measuring system in terms of defect size, depth, and the size-to-depth ratio. The results showed that the surface characteristics of the PBF-EB are critical for thermography.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/3004904
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo