In this study, we developed and validated a fully automatic system based on pretreatment MRI to predict resistance to therapy in rectal cancer patients using a multi-center and multi-vendor database. Tumors were automatically segmented using in-house automatic U-Net segmentations and subsequently classified as responder and non-responder through a Random Forest algorithm that was fed with a subset of features selected by a customized features selection approach. Despite the strong imbalance between the two classes, the performances yielded are promising, with an area under the curve of 0.72 and a balanced accuracy of 66% on the external validation set. Even if further analyses are still required to improve the performance, our results represent a further step towards a more personalized medicine for patients with rectal cancer.
A Fully Automatic Multi-Vendor AI-System To Segment And Predict Resistance To Treatment Of Rectal Cancer On MRI / Panic, J.; Defeudis, A.; Vassallo, L.; Cirillo, S.; Gatti, M.; Esposito, A.; Dell'Aversana, S.; Siena, S.; Vanzulli, A.; Regge, D.; Rosati, S.; Balestra, G.; Giannini, V.. - ELETTRONICO. - (2024). (Intervento presentato al convegno 10th World Congress on New Technologies, NewTech 2024 tenutosi a Barcelona (Spa) nel August 25-27, 2024) [10.11159/icbb24.120].
A Fully Automatic Multi-Vendor AI-System To Segment And Predict Resistance To Treatment Of Rectal Cancer On MRI
Panic J.;Rosati S.;Balestra G.;Giannini V.
2024
Abstract
In this study, we developed and validated a fully automatic system based on pretreatment MRI to predict resistance to therapy in rectal cancer patients using a multi-center and multi-vendor database. Tumors were automatically segmented using in-house automatic U-Net segmentations and subsequently classified as responder and non-responder through a Random Forest algorithm that was fed with a subset of features selected by a customized features selection approach. Despite the strong imbalance between the two classes, the performances yielded are promising, with an area under the curve of 0.72 and a balanced accuracy of 66% on the external validation set. Even if further analyses are still required to improve the performance, our results represent a further step towards a more personalized medicine for patients with rectal cancer.File | Dimensione | Formato | |
---|---|---|---|
2024_World Congress on New Technologies_A Fully Automatic Multi-Vendor AI-System To Segment And Predict Resistance To Treatment Of Rectal Cancer On MRI.pdf
accesso aperto
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
582.41 kB
Formato
Adobe PDF
|
582.41 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2999425