The paper presents a two-dimensional thermal model coupled with the electrical model to investigate the performance of a PV module. An iterative procedure is implemented by calculating analytically the boundary conditions for each cell of the PV module placed in the environment, considering the effect of solar irradiance and Joule heating. The temperature distribution is then calculated in each cell using a numerical model where an accurate description of connections is included. The electric current can be calculated inside each cell, starting from cell temperature distributions. An updated source term, including Joule dissipation, is evaluated to enhance boundary conditions by applying the eigenfunctions expansion method. Stationary solutions are obtained at the end of the iterative procedure showing the effects of Joule dissipation on the module performance. The effects of environmental conditions, irradiance and ambient temperature on the module temperature are also investigated.
Semi-Analytical Electro-Thermal Modelling of a Photovoltaic Module for Evaluation of Spatial Temperature Distribution / Amodio, A.; D'Angola, A.; Enescu, D.; Ferraro, A.; Malgaroli, G.; Spertino, F.. - ELETTRONICO. - (2023), pp. 1-6. (Intervento presentato al convegno 2023 58th International Universities Power Engineering Conference (UPEC) tenutosi a Dublin (Ireland) nel 30 August 2023 - 01 September 2023) [10.1109/UPEC57427.2023.10294652].
Semi-Analytical Electro-Thermal Modelling of a Photovoltaic Module for Evaluation of Spatial Temperature Distribution
Malgaroli G.;Spertino F.
2023
Abstract
The paper presents a two-dimensional thermal model coupled with the electrical model to investigate the performance of a PV module. An iterative procedure is implemented by calculating analytically the boundary conditions for each cell of the PV module placed in the environment, considering the effect of solar irradiance and Joule heating. The temperature distribution is then calculated in each cell using a numerical model where an accurate description of connections is included. The electric current can be calculated inside each cell, starting from cell temperature distributions. An updated source term, including Joule dissipation, is evaluated to enhance boundary conditions by applying the eigenfunctions expansion method. Stationary solutions are obtained at the end of the iterative procedure showing the effects of Joule dissipation on the module performance. The effects of environmental conditions, irradiance and ambient temperature on the module temperature are also investigated.File | Dimensione | Formato | |
---|---|---|---|
Post-non-editoriale.pdf
accesso aperto
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
856.02 kB
Formato
Adobe PDF
|
856.02 kB | Adobe PDF | Visualizza/Apri |
Post-editoriale.pdf
accesso riservato
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
623.3 kB
Formato
Adobe PDF
|
623.3 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2997559