This Supplementary Comparison, EURAMET.QM-S15 "PAHs in Protein Matrix", was organized by the Federal Institute of Metrology METAS. The target analytes were four PAHs: benz[a]anthracene (BaA); benzo[a]pyrene (BaP); benzo[b]fluoranthene (BbF); and chrysene (Chr), for which maximum limits are set in the European and Swiss food legislation. The measurands were the mass fractions of these PAHs in a protein-rich matrix. Six National Metrology Institutions (NMIs) and Designated Institutes (DIs) participated in EURAMET.QM-S15. The study required solvent extraction, separation of the target analytes from interfering matrix components (clean-up), analytical/chromatographic separation and selective detection of the target analytes. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

PAHs in protein matrix / Lobsiger, Simon; Umbricht, Gisela; Mallia, Silvia; Bilsel, Mine; Gökçen, Taner; Akkuş Özen, Şükran; Kaminski, Martin; Zübner, Isabella; Đokić Vasić, Dragana; Bešter, Erika; Valenčič, Vasilij; Portesi, Chiara; Schiavone, Consolato; Romaniello, Francesco. - In: METROLOGIA. - ISSN 0026-1394. - ELETTRONICO. - 61:1A(2024). [10.1088/0026-1394/61/1a/08018]

PAHs in protein matrix

Schiavone, Consolato;
2024

Abstract

This Supplementary Comparison, EURAMET.QM-S15 "PAHs in Protein Matrix", was organized by the Federal Institute of Metrology METAS. The target analytes were four PAHs: benz[a]anthracene (BaA); benzo[a]pyrene (BaP); benzo[b]fluoranthene (BbF); and chrysene (Chr), for which maximum limits are set in the European and Swiss food legislation. The measurands were the mass fractions of these PAHs in a protein-rich matrix. Six National Metrology Institutions (NMIs) and Designated Institutes (DIs) participated in EURAMET.QM-S15. The study required solvent extraction, separation of the target analytes from interfering matrix components (clean-up), analytical/chromatographic separation and selective detection of the target analytes. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
File in questo prodotto:
File Dimensione Formato  
EURAMET.QM-S15.pdf

accesso riservato

Descrizione: SUPPLEMENTARY COMPARISON on PAHs in protein matrix
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 3.68 MB
Formato Adobe PDF
3.68 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
EURAMET.QM-S15_Final_Report.pdf

embargo fino al 24/12/2025

Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: Pubblico - Tutti i diritti riservati
Dimensione 3.68 MB
Formato Adobe PDF
3.68 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2996296