This study presents a novel approach for EEG-based seizure detection leveraging a BERT-based model. The model, BENDR, undergoes a two-phase training process. Initially, it is pre-trained on the extensive Temple University Hospital EEG Corpus (TUEG), a 1.5 TB dataset comprising over 10,000 subjects, to extract common EEG data patterns. Subsequently, the model is fine-tuned on the CHB-MIT Scalp EEG Database, consisting of 664 EEG recordings from 24 pediatric patients, of which 198 contain seizure events. Key contributions include optimizing fine-tuning on the CHB-MIT dataset, where the impact of model architecture, pre-processing, and post-processing techniques are thoroughly examined to enhance sensitivity and reduce false positives per hour (FP/h). We also explored custom training strategies to ascertain the most effective setup. The model undergoes a novel second pre-training phase before subject-specific fine-tuning, enhancing its generalization capabilities. The optimized model demonstrates substantial performance enhancements, achieving as low as 0.23 FP/h, 2.5x lower than the baseline model, with a lower but still acceptable sensitivity rate, showcasing the effectiveness of applying a BERT-based approach on EEG-based seizure detection.
BISeizuRe: BERT-Inspired Seizure Data Representation to Improve Epilepsy Monitoring / Benfenati, Luca; Mar Ingolfsson, Thorir; Cossettini, Andrea; Jahier Pagliari, Daniele; Burrello, Alessio; Benini, Luca. - ELETTRONICO. - (2024). (Intervento presentato al convegno 2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) tenutosi a Orlando (USA) nel 15-19 July 2024) [10.1109/EMBC53108.2024.10782289].
BISeizuRe: BERT-Inspired Seizure Data Representation to Improve Epilepsy Monitoring
Benfenati,Luca;Jahier Pagliari,Daniele;Burrello,Alessio;Benini,Luca
2024
Abstract
This study presents a novel approach for EEG-based seizure detection leveraging a BERT-based model. The model, BENDR, undergoes a two-phase training process. Initially, it is pre-trained on the extensive Temple University Hospital EEG Corpus (TUEG), a 1.5 TB dataset comprising over 10,000 subjects, to extract common EEG data patterns. Subsequently, the model is fine-tuned on the CHB-MIT Scalp EEG Database, consisting of 664 EEG recordings from 24 pediatric patients, of which 198 contain seizure events. Key contributions include optimizing fine-tuning on the CHB-MIT dataset, where the impact of model architecture, pre-processing, and post-processing techniques are thoroughly examined to enhance sensitivity and reduce false positives per hour (FP/h). We also explored custom training strategies to ascertain the most effective setup. The model undergoes a novel second pre-training phase before subject-specific fine-tuning, enhancing its generalization capabilities. The optimized model demonstrates substantial performance enhancements, achieving as low as 0.23 FP/h, 2.5x lower than the baseline model, with a lower but still acceptable sensitivity rate, showcasing the effectiveness of applying a BERT-based approach on EEG-based seizure detection.File | Dimensione | Formato | |
---|---|---|---|
Transformer_Seizure_Detection____EMBC_2024_IRIS.pdf
accesso aperto
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
269.4 kB
Formato
Adobe PDF
|
269.4 kB | Adobe PDF | Visualizza/Apri |
BISeizuRe_BERT-Inspired_Seizure_Data_Representation_to_Improve_Epilepsy_Monitoring.pdf
accesso riservato
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
300.6 kB
Formato
Adobe PDF
|
300.6 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2992625