Memristor biosensors are electronic systems very recently born electronic systems in the quest for highly sensitive biodetection approaches. The presence of charged species in the vicinity of a semiconductor channel connecting a source and a drain electrode opens a voltage gap between the two current minima in the semi-logarithmic output curve. Despite the tremendous sensitivity demonstrated in the past, the initial state of the gap limits the charge sign of the analyte to be detected, i.e. with an initial closed gap the detection of analytes with a gap-closing effect will remain challenging. Here, we propose a gap controlling process using a third electrode that mimics the presence of charged molecules of the desired sign. We test the function of the gapcontrol terminal via a back-gate in dry condition and we demonstrate the operation in liquid environment using a top-gate electrode. Finally, toward (bio)chemical sensing applications, we discriminate solutions with different pH values. The hereby proposed method is critical to allow broadening the range of analytes that can be sensed directly in liquid environment regardless their charge sign.

Gap engineering for improved control of memristor nanosensors / Ibarlucea, B; Baraban, L; Cuniberti, G; Kim, K; Rim, T; Baek, C-K; Ascoli, A; Tetzlaff, R. - ELETTRONICO. - (2017). (Intervento presentato al convegno European Conference on Circuit Theory and Design (ECCTD) tenutosi a Catania (Italy) nel 04-06 September 2017) [10.1109/ECCTD.2017.8093293].

Gap engineering for improved control of memristor nanosensors

Ascoli A;
2017

Abstract

Memristor biosensors are electronic systems very recently born electronic systems in the quest for highly sensitive biodetection approaches. The presence of charged species in the vicinity of a semiconductor channel connecting a source and a drain electrode opens a voltage gap between the two current minima in the semi-logarithmic output curve. Despite the tremendous sensitivity demonstrated in the past, the initial state of the gap limits the charge sign of the analyte to be detected, i.e. with an initial closed gap the detection of analytes with a gap-closing effect will remain challenging. Here, we propose a gap controlling process using a third electrode that mimics the presence of charged molecules of the desired sign. We test the function of the gapcontrol terminal via a back-gate in dry condition and we demonstrate the operation in liquid environment using a top-gate electrode. Finally, toward (bio)chemical sensing applications, we discriminate solutions with different pH values. The hereby proposed method is critical to allow broadening the range of analytes that can be sensed directly in liquid environment regardless their charge sign.
2017
978-1-5386-3974-0
File in questo prodotto:
File Dimensione Formato  
Gap engineering for improved control of memristor nanosensors.pdf

accesso riservato

Descrizione: Contributo in Atti di convegno
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 348.82 kB
Formato Adobe PDF
348.82 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2988718