We report the result of the new absolute frequency measurement of 171Yb performed at INRIM. The frequency of our optical lattice clock IT-Yb1 is measured against the local cryogenic Cs fountain IT-CsF2 during a campaign that lasted 14 months. The frequency measurements were performed with two different techniques, i.e. using a hydrogen maser as a transfer oscillator or by synthesizing a low-noise microwave for the Cs interrogation from the Yb ultrastable laser with an optical frequency comb. The frequency of the Yb unperturbed clock transition is 518 295 836 590 863.44(14) Hz, with a total fractional uncertainty of 2.7 × 10-16, limited by the uncertainty of IT-CsF2. This is the absolute frequency measurement of a Yb clock against a Cs fountain with the lowest uncertainty. The result agrees with the Yb frequency value recommended by the Consultative Committee for Time and Frequency (CCTF). Moreover, the Yb data acquired during this campaign have been submitted to the Bureau of Weights and Measures (BIPM) to contribute to the calibration of the International Atomic Time (TAI). This work confirms the reliability of Yb as a secondary representation of the second.
IT-Yb1 Optical Lattice Clock: Absolute Frequency Measurement at the Cs Fountain Uncertainty Level / Goti, I.; Condio, S.; Clivati, C.; Risaro, M.; Gozzelino, M.; Costanzo, G. A.; Levi, F.; Calonico, D.; Pizzocaro, M.. - ELETTRONICO. - (2023). (Intervento presentato al convegno 2023 Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) tenutosi a Toyama, Japan nel 15-19 May 2023) [10.1109/eftf/ifcs57587.2023.10272188].
IT-Yb1 Optical Lattice Clock: Absolute Frequency Measurement at the Cs Fountain Uncertainty Level
Condio, S.;Costanzo, G. A.;
2023
Abstract
We report the result of the new absolute frequency measurement of 171Yb performed at INRIM. The frequency of our optical lattice clock IT-Yb1 is measured against the local cryogenic Cs fountain IT-CsF2 during a campaign that lasted 14 months. The frequency measurements were performed with two different techniques, i.e. using a hydrogen maser as a transfer oscillator or by synthesizing a low-noise microwave for the Cs interrogation from the Yb ultrastable laser with an optical frequency comb. The frequency of the Yb unperturbed clock transition is 518 295 836 590 863.44(14) Hz, with a total fractional uncertainty of 2.7 × 10-16, limited by the uncertainty of IT-CsF2. This is the absolute frequency measurement of a Yb clock against a Cs fountain with the lowest uncertainty. The result agrees with the Yb frequency value recommended by the Consultative Committee for Time and Frequency (CCTF). Moreover, the Yb data acquired during this campaign have been submitted to the Bureau of Weights and Measures (BIPM) to contribute to the calibration of the International Atomic Time (TAI). This work confirms the reliability of Yb as a secondary representation of the second.File | Dimensione | Formato | |
---|---|---|---|
IT-Yb1_Optical_Lattice_Clock_Absolute_Frequency_Measurement_at_the_Cs_Fountain_Uncertainty_Level.pdf
accesso riservato
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
933 kB
Formato
Adobe PDF
|
933 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
AbstractGoti_EFTF2023 (1).pdf
accesso aperto
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
266.45 kB
Formato
Adobe PDF
|
266.45 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2987228