In preparation for the upcoming deuterium-tritium campaign at the JET tokamak, the ex-vessel fission chamber neutron diagnostics and the neutron activation system will be calibrated in absolute terms at 14 MeV neutron energy, to a required accuracy of less than 10%. Two nominally identical DT neutron generators were chosen as the calibration sources, both of which were fully calibrated and characterized at the UK's National Physical Laboratory. The neutron activation method was adopted as a complementary method for the purpose of determining the absolute value of the neutron yield from the neutron generators and to provide a means of cross check for the active detection methods being employed. The work being presented here shows the derivation of the neutron emission rate from the neutron generators based upon experimental activation foil measurements.
Activation measurements in support of the 14 MeV neutron calibration of JET neutron monitors / Jednorog, S.; Laszynska, E.; Batistoni, P.; Bienkowska, B.; Cufar, A.; Ghani, Z.; Giacomelli, L.; Klix, A.; Loreti, S.; Mikszuta, K.; Packer, L.; Peacock, A.; Pillon, M.; Popovichev, S.; Rebai, M.; Rigamonti, D.; Roberts, N.; Tardocchi, M.; Thomas, D.; Subba, F.. - In: FUSION ENGINEERING AND DESIGN. - ISSN 0920-3796. - 125:(2017), pp. 50-56. [10.1016/j.fusengdes.2017.10.024]
Activation measurements in support of the 14 MeV neutron calibration of JET neutron monitors
Subba, F.
2017
Abstract
In preparation for the upcoming deuterium-tritium campaign at the JET tokamak, the ex-vessel fission chamber neutron diagnostics and the neutron activation system will be calibrated in absolute terms at 14 MeV neutron energy, to a required accuracy of less than 10%. Two nominally identical DT neutron generators were chosen as the calibration sources, both of which were fully calibrated and characterized at the UK's National Physical Laboratory. The neutron activation method was adopted as a complementary method for the purpose of determining the absolute value of the neutron yield from the neutron generators and to provide a means of cross check for the active detection methods being employed. The work being presented here shows the derivation of the neutron emission rate from the neutron generators based upon experimental activation foil measurements.File | Dimensione | Formato | |
---|---|---|---|
53099_manuscript_revised.pdf
accesso aperto
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Creative commons
Dimensione
2.39 MB
Formato
Adobe PDF
|
2.39 MB | Adobe PDF | Visualizza/Apri |
1-s2.0-S0920379617308918-main.pdf
non disponibili
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
1.04 MB
Formato
Adobe PDF
|
1.04 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2986863