Concrete spatial architecture was mainly built using techniques that at the time were still experimental and based on design criteria that did not consider seismic actions. The validity of accurate models accounting for such complex structural schemes can be demonstrated, but the latter still would not support a clear comparison with the original predictions. Different from other Morandi’s balanced beam schemes, in the underground Pavilion V of Turin Exhibition Center the main post-tensioned ribs are not parallel beams but are diagonally directed and multiply reciprocally interconnected in order to obtain a spatial structure offering a high overall rigidity and lateral stability, and to contrast the instability of the very thin webs of the main ribs. The paper focuses on how information from the experimental campaign can help to formulate virtual models for prognostic and diagnostic assessments under different scenarios, such as for example the design of structural health monitoring activities and systems.
Digital Twinning for the Prognosis of Spatial Architectures: Morandi’s Underground Pavilion in Turin / Miraglia, G.; Cavanni, V.; Crocetti, A.; Lenticchia, E.; Oliva, V.; Scussolini, L.; Ceravolo, R.. - (2024), pp. 765-774. (Intervento presentato al convegno 2nd Italian Workshop on Shell and Spatial Structures, IWSS 2023 tenutosi a Turin (Italy) nel 26-28 June 2023) [10.1007/978-3-031-44328-2_80].
Digital Twinning for the Prognosis of Spatial Architectures: Morandi’s Underground Pavilion in Turin
Miraglia G.;Cavanni V.;Crocetti A.;Lenticchia E.;Oliva V.;Scussolini L.;Ceravolo R.
2024
Abstract
Concrete spatial architecture was mainly built using techniques that at the time were still experimental and based on design criteria that did not consider seismic actions. The validity of accurate models accounting for such complex structural schemes can be demonstrated, but the latter still would not support a clear comparison with the original predictions. Different from other Morandi’s balanced beam schemes, in the underground Pavilion V of Turin Exhibition Center the main post-tensioned ribs are not parallel beams but are diagonally directed and multiply reciprocally interconnected in order to obtain a spatial structure offering a high overall rigidity and lateral stability, and to contrast the instability of the very thin webs of the main ribs. The paper focuses on how information from the experimental campaign can help to formulate virtual models for prognostic and diagnostic assessments under different scenarios, such as for example the design of structural health monitoring activities and systems.File | Dimensione | Formato | |
---|---|---|---|
IWSS Proceedings Miraglia et al.pdf
non disponibili
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
2.92 MB
Formato
Adobe PDF
|
2.92 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2984512