Microwave imaging can represent an alternative for in-line inspection of food products, to reveal the presence of possible foreign bodies that may have contaminated the product during the transformation and/or packaging stages. To this end, a microwave system specifically meant for such purpose has been recently proposed. With respect to this device, a novel imaging strategy is presented, which allows one to build the image of the target without the need of a contaminant-free item used as reference sample. The idea is still to perform a differential imaging taking advantage of possible symmetries of the object under test with respect to the imaging system. These symmetries only occurred in a contaminant-free item, while are broken by the presence of an inclusion, thus revealing their presence. A quite common case is that of food packaged in circular plastic/glass jars. A simple numerical example is provided showing the capabilities of the approach.
A Simple Imaging Strategy for In-Line food Inspection via Microwave Imaging / Bellizzi, G.; Crocco, L.; Cavagnaro, M.; Ricci, M.; Vasquez, J. A. T.; Vipiana, F.. - ELETTRONICO. - (2022). (Intervento presentato al convegno 16th European Conference on Antennas and Propagation, EuCAP 2022 tenutosi a Madrid, Spain nel 27 March 2022 - 01 April 2022) [10.23919/EuCAP53622.2022.9768949].
A Simple Imaging Strategy for In-Line food Inspection via Microwave Imaging
Crocco L.;Ricci M.;Vipiana F.
2022
Abstract
Microwave imaging can represent an alternative for in-line inspection of food products, to reveal the presence of possible foreign bodies that may have contaminated the product during the transformation and/or packaging stages. To this end, a microwave system specifically meant for such purpose has been recently proposed. With respect to this device, a novel imaging strategy is presented, which allows one to build the image of the target without the need of a contaminant-free item used as reference sample. The idea is still to perform a differential imaging taking advantage of possible symmetries of the object under test with respect to the imaging system. These symmetries only occurred in a contaminant-free item, while are broken by the presence of an inclusion, thus revealing their presence. A quite common case is that of food packaged in circular plastic/glass jars. A simple numerical example is provided showing the capabilities of the approach.File | Dimensione | Formato | |
---|---|---|---|
1570770367 paper BELLIZZI.pdf
accesso aperto
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
PUBBLICO - Tutti i diritti riservati
Dimensione
891.38 kB
Formato
Adobe PDF
|
891.38 kB | Adobe PDF | Visualizza/Apri |
Vipiana-ASimple.pdf
non disponibili
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
803.22 kB
Formato
Adobe PDF
|
803.22 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2982069