This paper reports on large-scale loading tests survey carried out on 50-year-oldprestressed concrete girders as part of the BRIDGE|50 research project (www.bridge50.org).The girders were retrieved from an existing viaduct in Turin, Italy. The prestressed concreteelements were 19.2 m long and had an I-shaped cross-section with a cast-in-situ slab. Variabledamages were found, due to in-service deterioration and/or subsequent lifting operations duringthe demolition phase. Each specimen was subjected to static tests using monotonic or cyclicloading up to the ultimate load. This paper reports the results of tests on the second group offour girders, comparing their load-deflection responses and strains with those of the first groupsubjected to a different static scheme. The experimental findings highlight the global structuralresponse from bending to bending/shear failure; the outcomes will define a valuable referencedatabase for assessing the residual structural performance of existing girder bridges.

Large-scale experimental testing of 50-year-old prestressed concrete bridge girder / Savino, Pierclaudio; Quattrone, Antonino; Sabia, Donato; Chiaia, Bernardino; Tondolo, Francesco; Anghileri, Mattia; Biondini, Fabio; Rosati, Gianpaolo. - ELETTRONICO. - (2023), pp. 2061-2068. (Intervento presentato al convegno 8th International Symposium on Life-Cycle Civil Engineering. IALCCE 2023 tenutosi a Milan (Italy) nel 2-6 July, 2023) [10.1201/9781003323020-2522061].

Large-scale experimental testing of 50-year-old prestressed concrete bridge girder

Savino, Pierclaudio;Quattrone, Antonino;Sabia, Donato;Chiaia, Bernardino;Tondolo, Francesco;
2023

Abstract

This paper reports on large-scale loading tests survey carried out on 50-year-oldprestressed concrete girders as part of the BRIDGE|50 research project (www.bridge50.org).The girders were retrieved from an existing viaduct in Turin, Italy. The prestressed concreteelements were 19.2 m long and had an I-shaped cross-section with a cast-in-situ slab. Variabledamages were found, due to in-service deterioration and/or subsequent lifting operations duringthe demolition phase. Each specimen was subjected to static tests using monotonic or cyclicloading up to the ultimate load. This paper reports the results of tests on the second group offour girders, comparing their load-deflection responses and strains with those of the first groupsubjected to a different static scheme. The experimental findings highlight the global structuralresponse from bending to bending/shear failure; the outcomes will define a valuable referencedatabase for assessing the residual structural performance of existing girder bridges.
2023
978-1-003-32302-0
File in questo prodotto:
File Dimensione Formato  
1.pdf

accesso aperto

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 1.67 MB
Formato Adobe PDF
1.67 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2981553