Data-driven Automated Fault Detection and Diagnosis (AFDD) is the automated process of detecting devi-ations (faults) from normal operation and diagnosing the type of problem and/or its location based on the exploitation of data collected under normal and faulty conditions. The performance of a typical single -duct dual-fan constant air volume air-handling unit (AHU) are investigated through a number of exper-iments performed during Italian cooling and heating seasons under both fault free and faulty scenarios. The AHU operation is analysed while artificially introducing six typical faults: 1) positive offset (+3 degrees C) of the return air temperature sensor; 2) negative offset (-3 degrees C) of the return air temperature sensor; 3) pos-itive offset (+15 %) of the return air relative humidity sensor; 4) negative offset (-15 %) of the return air relative humidity sensor; 5) complete failure of the return air fan; 6) complete failure of the supply air fan. The faulty tests are compared with the fault free experiments performed under the same boundary conditions to assess the impacts of the faults on both thermal/hygrometric indoor comfort and patterns of key operating parameters with the aim of supporting the studies focusing on new and accurate data -driven AFDD methods for AHUs. (c) 2022 Elsevier B.V. All rights reserved.
Experimental assessment of ground-truth faults in a typical single-duct dual-fan air-handling unit under Mediterranean climatic conditions: Impact scenarios of sensors? offset and fans? failure / Rosato, A; Guarino, F; El Youssef, M; Capozzoli, A; Masullo, M; Maffei, L. - In: ENERGY AND BUILDINGS. - ISSN 0378-7788. - ELETTRONICO. - 275:(2022), p. 112492. [10.1016/j.enbuild.2022.112492]
Experimental assessment of ground-truth faults in a typical single-duct dual-fan air-handling unit under Mediterranean climatic conditions: Impact scenarios of sensors? offset and fans? failure
Capozzoli, A;
2022
Abstract
Data-driven Automated Fault Detection and Diagnosis (AFDD) is the automated process of detecting devi-ations (faults) from normal operation and diagnosing the type of problem and/or its location based on the exploitation of data collected under normal and faulty conditions. The performance of a typical single -duct dual-fan constant air volume air-handling unit (AHU) are investigated through a number of exper-iments performed during Italian cooling and heating seasons under both fault free and faulty scenarios. The AHU operation is analysed while artificially introducing six typical faults: 1) positive offset (+3 degrees C) of the return air temperature sensor; 2) negative offset (-3 degrees C) of the return air temperature sensor; 3) pos-itive offset (+15 %) of the return air relative humidity sensor; 4) negative offset (-15 %) of the return air relative humidity sensor; 5) complete failure of the return air fan; 6) complete failure of the supply air fan. The faulty tests are compared with the fault free experiments performed under the same boundary conditions to assess the impacts of the faults on both thermal/hygrometric indoor comfort and patterns of key operating parameters with the aim of supporting the studies focusing on new and accurate data -driven AFDD methods for AHUs. (c) 2022 Elsevier B.V. All rights reserved.File | Dimensione | Formato | |
---|---|---|---|
Experimental assessment of ground truth faults.pdf
non disponibili
Descrizione: Experimental assessment of ground truth faults
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
3.99 MB
Formato
Adobe PDF
|
3.99 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
ENB-S-22-02587_postprint.pdf
Open Access dal 22/09/2024
Descrizione: postprint
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Creative commons
Dimensione
3.46 MB
Formato
Adobe PDF
|
3.46 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2974680