The accurate determination of mass transport and microstructural properties within highly-porous trabecular bone specimens and substitutes still represents a challenge due to the complex arrangement in the three-dimensional space, where adjacent pores can be hardly identified due to the open-cell disordered structure resulting from the reciprocal alternation of struts and voids. In the present study, the complete set of mass transport properties of hydroxyapatite (HA) scaffolds produced by digital light processing (DLP)-based vat photopolymerization was determined by applying the recent Ergun-Wu resistance model. Input data include the intrinsic permeability of the scaffolds, obtained by acoustic experimental measurements, and the equivalent pore diameter, calculated as a function of total porosity and average trabecular size from accurate micro-computed tomography (μ-CT) scans. The results, corroborated by an accurate and robust statistical analysis, were compared with previous literature data and confirmed a feasible and concrete application of DLP-derived HA scaffolds in clinical practice.
High-reliability data processing and calculation of microstructural parameters in hydroxyapatite scaffolds produced by vat photopolymerization / Schiavi, A.; Fiume, E.; Orlygsson, G.; Schwentenwein, M.; Verne', E.; Baino, F.. - In: JOURNAL OF THE EUROPEAN CERAMIC SOCIETY. - ISSN 0955-2219. - ELETTRONICO. - 42:13(2022), pp. 6206-6212. [10.1016/j.jeurceramsoc.2022.06.022]
High-reliability data processing and calculation of microstructural parameters in hydroxyapatite scaffolds produced by vat photopolymerization
Fiume E.;Verne' E.;Baino F.
2022
Abstract
The accurate determination of mass transport and microstructural properties within highly-porous trabecular bone specimens and substitutes still represents a challenge due to the complex arrangement in the three-dimensional space, where adjacent pores can be hardly identified due to the open-cell disordered structure resulting from the reciprocal alternation of struts and voids. In the present study, the complete set of mass transport properties of hydroxyapatite (HA) scaffolds produced by digital light processing (DLP)-based vat photopolymerization was determined by applying the recent Ergun-Wu resistance model. Input data include the intrinsic permeability of the scaffolds, obtained by acoustic experimental measurements, and the equivalent pore diameter, calculated as a function of total porosity and average trabecular size from accurate micro-computed tomography (μ-CT) scans. The results, corroborated by an accurate and robust statistical analysis, were compared with previous literature data and confirmed a feasible and concrete application of DLP-derived HA scaffolds in clinical practice.File | Dimensione | Formato | |
---|---|---|---|
Manuscript HAp scaffolds_R1.pdf
Open Access dal 09/06/2024
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Creative commons
Dimensione
1.05 MB
Formato
Adobe PDF
|
1.05 MB | Adobe PDF | Visualizza/Apri |
DLP HAp scaffolds modelling_JECS 2022.pdf
accesso riservato
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
1.89 MB
Formato
Adobe PDF
|
1.89 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2973795