This article proposes the characterization of stimulation and detection equipment in the design of wearable brain;computer interfaces (BCIs) based on visually evoked potentials. In particular, methods for the characterization of the optical output of commercial smart glasses and for the calibration of a low-cost electroencephalograph (EEG) are presented and discussed. The reported results show that, by proper characterization and calibration, consumer-grade equipment is suitable for BCI applications. Moreover, unexpected harmonics of the visual stimuli have to be taken into account by suitable processing. Finally, the EEG shows an adequate linear behavior, but its gain error of around 10 & x0025; should be corrected by calibration in some applications.

Metrological characterization of consumer-grade equipment for wearable brain-computer interfaces and extended reality / Arpaia, P; Callegaro, L; Cultrera, A; Esposito, A; Ortolano, M. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - STAMPA. - 71:(2022), p. 4002209. [10.1109/TIM.2021.3127650]

Metrological characterization of consumer-grade equipment for wearable brain-computer interfaces and extended reality

Esposito, A;Ortolano, M
2022

Abstract

This article proposes the characterization of stimulation and detection equipment in the design of wearable brain;computer interfaces (BCIs) based on visually evoked potentials. In particular, methods for the characterization of the optical output of commercial smart glasses and for the calibration of a low-cost electroencephalograph (EEG) are presented and discussed. The reported results show that, by proper characterization and calibration, consumer-grade equipment is suitable for BCI applications. Moreover, unexpected harmonics of the visual stimuli have to be taken into account by suitable processing. Finally, the EEG shows an adequate linear behavior, but its gain error of around 10 & x0025; should be corrected by calibration in some applications.
File in questo prodotto:
File Dimensione Formato  
2021_Arpaia_Metrological_characterization_of_consumer-grade_equipment_for_wearable_brain-computer_interfaces_and_extended_reality_early_access.pdf

accesso aperto

Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 1.87 MB
Formato Adobe PDF
1.87 MB Adobe PDF Visualizza/Apri
Ortolano-Metrological.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 1.94 MB
Formato Adobe PDF
1.94 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2971065