FASER, the ForwArd Search ExpeRiment, is designed to search for new, yet undiscovered, light and weakly-interacting particles and study the interactions of high-energy neutrinos. Three dipoles, one 1.5 m-long and the other two 1.0 m-long each, installed upstream of the ATLAS experiment at CERN, are required to achieve sufficient separation of pairs of oppositely charged, high-energy Standard Model particles originating from decays of new physics particles. The dipoles have an aperture of 200 mm in diameter and a required magnetic field at the centre ≥ 0.55 T. Due to tight space constraints, a design based on permanent magnet technology was proposed. This paper describes the design, manufacturing, assembly and magnetic measurement of these large Halbach array dipoles.
Design, Manufacture and Measurement of three Permanent Magnet Dipoles for FASER Experiment / Thonet, P. A.; Dunkel, O.; Liebsch, M.; Pentella, M.; Petrone, C.. - In: IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY. - ISSN 1051-8223. - ELETTRONICO. - 32:6(2022), pp. 1-5. [10.1109/TASC.2022.3191284]
Design, Manufacture and Measurement of three Permanent Magnet Dipoles for FASER Experiment
Pentella, M.;
2022
Abstract
FASER, the ForwArd Search ExpeRiment, is designed to search for new, yet undiscovered, light and weakly-interacting particles and study the interactions of high-energy neutrinos. Three dipoles, one 1.5 m-long and the other two 1.0 m-long each, installed upstream of the ATLAS experiment at CERN, are required to achieve sufficient separation of pairs of oppositely charged, high-energy Standard Model particles originating from decays of new physics particles. The dipoles have an aperture of 200 mm in diameter and a required magnetic field at the centre ≥ 0.55 T. Due to tight space constraints, a design based on permanent magnet technology was proposed. This paper describes the design, manufacturing, assembly and magnetic measurement of these large Halbach array dipoles.File | Dimensione | Formato | |
---|---|---|---|
Design_Manufacture_and_Measurement_of_three_Permanent_Magnet_Dipoles_for_FASER_Experiment.pdf
accesso aperto
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
PUBBLICO - Tutti i diritti riservati
Dimensione
697.67 kB
Formato
Adobe PDF
|
697.67 kB | Adobe PDF | Visualizza/Apri |
Pentella-Design.pdf
non disponibili
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
3.69 MB
Formato
Adobe PDF
|
3.69 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2970486