In the framework of bioimpedance spectroscopy-based insulin bioavailability assessment, a preliminary experimental campaign aimed to investigate the relationship between applied pressure and impedance variation was conducted. The experimental tests were carried out on a volunteer's abdomen in a controlled environment. They exploited four pre-gelled electrodes and a non- invasive instrument built with off-the-shelf components, namely DUSM, previously successfully used by the authors in different biomedical applications. Experimental results are compatible with the scientific literature, and show a progressive increase of the impedance magnitude according to an increasing external force which is comparable to the typical mechanical action of an insulin injection.
Preliminary Investigation of the impact of mechanical stresses on bioimpedance spectroscopy-based insuline bioavailability assessment / Arpaia, Pasquale.; Cuneo, Davide; Mancino, Francesca; Minucci, Simone; Moccaldi, Nicola; Sannino, Isabella.. - ELETTRONICO. - (2021), pp. 52-55. (Intervento presentato al convegno 14th International Workshop on Impedance Spectroscopy, IWIS 2021 tenutosi a Technische Universitat Chemnitz, deu nel 2021) [10.1109/IWIS54661.2021.9711756].
Preliminary Investigation of the impact of mechanical stresses on bioimpedance spectroscopy-based insuline bioavailability assessment
Sannino Isabella.
2021
Abstract
In the framework of bioimpedance spectroscopy-based insulin bioavailability assessment, a preliminary experimental campaign aimed to investigate the relationship between applied pressure and impedance variation was conducted. The experimental tests were carried out on a volunteer's abdomen in a controlled environment. They exploited four pre-gelled electrodes and a non- invasive instrument built with off-the-shelf components, namely DUSM, previously successfully used by the authors in different biomedical applications. Experimental results are compatible with the scientific literature, and show a progressive increase of the impedance magnitude according to an increasing external force which is comparable to the typical mechanical action of an insulin injection.File | Dimensione | Formato | |
---|---|---|---|
Preliminary_Investigation_of_the_Impact_of_Mechanical_Stresses_on_Bioimpedance_Spectroscopy-based_Insuline_Bioavailability_Assessment.pdf
accesso riservato
Descrizione: pdf
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
1.26 MB
Formato
Adobe PDF
|
1.26 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2962548