Due to their particular feature, DC Electric Arc Furnace (EAF) installations are peculiar loads that cause moderate to severe Power Quality (PQ) disturbances. Among them, voltage fluctuations and waveform distortions are the most impactful ones, and they should be adequately addressed in order to mitigate the detrimental effects on power systems. Several types of models have been developed in order to evaluate the effects of EAFs on networks, and chaotic models have been specifically recognized as suitable tools to evaluate the impact of EAFs in terms of PQ disturbances. This paper compares the performance of three chaotic models (Chua, Lorenz and Rossler) aiming at estimating PQ indices values of DC EAFs. An optimization procedure is proposed to find the parameters of the three chaotic models. The procedure exploits a block diagramming tool of the DC EAF installation and minimizes the deviation of estimated PQ indices from the actual ones. Actual data collected at an Italian DC EAF installation are used to conduct a numerical comparative analysis and to validate the effectiveness of the models in estimating the PQ disturbances.

Comparison of DC Electric Arc Furnace Chaotic Models for Power Quality Indices Assessment / Bracale, A.; Caramia, P.; Carpinelli, G.; De Falco, P.; Russo, A.. - (2020), pp. 1-6. (Intervento presentato al convegno 2020 IEEE International Conference on Environment and Electrical Engineering and 2020 IEEE Industrial and Commercial Power Systems Europe, EEEIC / I and CPS Europe 2020 tenutosi a esp nel June 9-12, 2020) [10.1109/EEEIC/ICPSEurope49358.2020.9160708].

Comparison of DC Electric Arc Furnace Chaotic Models for Power Quality Indices Assessment

Russo A.
2020

Abstract

Due to their particular feature, DC Electric Arc Furnace (EAF) installations are peculiar loads that cause moderate to severe Power Quality (PQ) disturbances. Among them, voltage fluctuations and waveform distortions are the most impactful ones, and they should be adequately addressed in order to mitigate the detrimental effects on power systems. Several types of models have been developed in order to evaluate the effects of EAFs on networks, and chaotic models have been specifically recognized as suitable tools to evaluate the impact of EAFs in terms of PQ disturbances. This paper compares the performance of three chaotic models (Chua, Lorenz and Rossler) aiming at estimating PQ indices values of DC EAFs. An optimization procedure is proposed to find the parameters of the three chaotic models. The procedure exploits a block diagramming tool of the DC EAF installation and minimizes the deviation of estimated PQ indices from the actual ones. Actual data collected at an Italian DC EAF installation are used to conduct a numerical comparative analysis and to validate the effectiveness of the models in estimating the PQ disturbances.
2020
978-1-7281-7455-6
File in questo prodotto:
File Dimensione Formato  
Comparison_of_DC_Electric_Arc_Furnace_Chaotic_Models_for_Power_Quality_Indices_Assessment-1.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 442.71 kB
Formato Adobe PDF
442.71 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2952596