Active gate drivers have been investigated in power circuits to reduce unwanted over-voltages and over-currents, whilst keeping the transients fast. Indeed, the use of such a kind of driver avoids the triggering of oscillations related to high frequency parasitic resonant circuits, which affect adversely the electro-magnetic interference delivered by power modules. However, in the case of fast power switches, the driver is working in an open-loop manner, and the modulation pattern is fixed. This paper assesses the effects of different operating conditions on the switching waveforms of an AGD-driven power transistor. More precisely, load current, input voltage and temperature variations were investigated on an open-loop active gate driver comprised in a Buck converter. Experimental results suggest that the AGD is no longer effective in damping the unwanted oscillations under a significant change of the operating conditions.
A Critical Assessment of Open-Loop Active Gate Drivers Under Variable Operating Conditions / Raviola, Erica; Fiori, Franco. - ELETTRONICO. - (2021), pp. 94-99. (Intervento presentato al convegno 2021 IEEE International Joint EMC/SI/PI and EMC Europe Symposium tenutosi a Glasgow, UK nel 26 July-13 Aug. 2021) [10.1109/EMC/SI/PI/EMCEurope52599.2021.9559173].
A Critical Assessment of Open-Loop Active Gate Drivers Under Variable Operating Conditions
Raviola, Erica;Fiori, Franco
2021
Abstract
Active gate drivers have been investigated in power circuits to reduce unwanted over-voltages and over-currents, whilst keeping the transients fast. Indeed, the use of such a kind of driver avoids the triggering of oscillations related to high frequency parasitic resonant circuits, which affect adversely the electro-magnetic interference delivered by power modules. However, in the case of fast power switches, the driver is working in an open-loop manner, and the modulation pattern is fixed. This paper assesses the effects of different operating conditions on the switching waveforms of an AGD-driven power transistor. More precisely, load current, input voltage and temperature variations were investigated on an open-loop active gate driver comprised in a Buck converter. Experimental results suggest that the AGD is no longer effective in damping the unwanted oscillations under a significant change of the operating conditions.| File | Dimensione | Formato | |
|---|---|---|---|
| critical_assess_open_loop_agd_er_ff.pdf accesso riservato 
											Descrizione: articolo principale
										 
											Tipologia:
											2a Post-print versione editoriale / Version of Record
										 
											Licenza:
											
											
												Non Pubblico - Accesso privato/ristretto
												
												
												
											
										 
										Dimensione
										6.82 MB
									 
										Formato
										Adobe PDF
									 | 6.82 MB | Adobe PDF | Visualizza/Apri Richiedi una copia | 
| agdSensitivity_author_ER_FF.pdf accesso aperto 
											Descrizione: Author version of the Paper
										 
											Tipologia:
											2. Post-print / Author's Accepted Manuscript
										 
											Licenza:
											
											
												Pubblico - Tutti i diritti riservati
												
												
												
											
										 
										Dimensione
										2.16 MB
									 
										Formato
										Adobe PDF
									 | 2.16 MB | Adobe PDF | Visualizza/Apri | 
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2935017
			
		
	
	
	
			      	