Active gate drivers have been investigated in power circuits to reduce unwanted over-voltages and over-currents, whilst keeping the transients fast. Indeed, the use of such a kind of driver avoids the triggering of oscillations related to high frequency parasitic resonant circuits, which affect adversely the electro-magnetic interference delivered by power modules. However, in the case of fast power switches, the driver is working in an open-loop manner, and the modulation pattern is fixed. This paper assesses the effects of different operating conditions on the switching waveforms of an AGD-driven power transistor. More precisely, load current, input voltage and temperature variations were investigated on an open-loop active gate driver comprised in a Buck converter. Experimental results suggest that the AGD is no longer effective in damping the unwanted oscillations under a significant change of the operating conditions.
A Critical Assessment of Open-Loop Active Gate Drivers Under Variable Operating Conditions / Raviola, Erica; Fiori, Franco. - ELETTRONICO. - (2021), pp. 94-99. (Intervento presentato al convegno 2021 IEEE International Joint EMC/SI/PI and EMC Europe Symposium tenutosi a Glasgow, UK nel 26 July-13 Aug. 2021) [10.1109/EMC/SI/PI/EMCEurope52599.2021.9559173].
A Critical Assessment of Open-Loop Active Gate Drivers Under Variable Operating Conditions
Raviola, Erica;Fiori, Franco
2021
Abstract
Active gate drivers have been investigated in power circuits to reduce unwanted over-voltages and over-currents, whilst keeping the transients fast. Indeed, the use of such a kind of driver avoids the triggering of oscillations related to high frequency parasitic resonant circuits, which affect adversely the electro-magnetic interference delivered by power modules. However, in the case of fast power switches, the driver is working in an open-loop manner, and the modulation pattern is fixed. This paper assesses the effects of different operating conditions on the switching waveforms of an AGD-driven power transistor. More precisely, load current, input voltage and temperature variations were investigated on an open-loop active gate driver comprised in a Buck converter. Experimental results suggest that the AGD is no longer effective in damping the unwanted oscillations under a significant change of the operating conditions.File | Dimensione | Formato | |
---|---|---|---|
critical_assess_open_loop_agd_er_ff.pdf
non disponibili
Descrizione: articolo principale
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
6.82 MB
Formato
Adobe PDF
|
6.82 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
agdSensitivity_author_ER_FF.pdf
accesso aperto
Descrizione: Author version of the Paper
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
PUBBLICO - Tutti i diritti riservati
Dimensione
2.16 MB
Formato
Adobe PDF
|
2.16 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2935017