The detection of anomalous power consumption in household appliances plays a key role for the optimization of grid operations and for reducing unwanted electrical absorptions in residential buildings. Smart Plugs, Smart Appliances and other appliance-level monitoring devices allow to continuously monitor the power consumption of individual appliances present in the house. This work is aimed at detecting electrical anomalies in household appliances by analyzing the disaggregated load consumption derived from appliance-level monitoring devices. For this purpose, we implemented an anomaly detection framework which monitors the hourly energy consumption of three common sources of power absorption: the baseline, the fridge and the electrical devices. Here, we focused our analysis on two kinds of anomalies: single-point deviations and anomalous trends. The analysis of single-point deviations allowed us to identify short-term power peaks due either to unexpected electrical faults or sudden variations in end-users routines. The analysis of anomalous trends revealed several cases in which the end-users gradually increased their ordinary power consumption profile towards more energy-intensive practices. In summary, the results of our work showed that the power consumption derived from appliance-level load monitoring can be used to detect several anomalous power consumption in household appliances.

Detection of Anomalies in Household Appliances from Disaggregated Load Consumption / Castangia, Marco; Sappa, Riccardo; Abraha Girmay, Awet; Camarda, Christian; Macii, Enrico; Patti, Edoardo. - (2021). (Intervento presentato al convegno 4th International Conference on Smart Energy Systems and Technologies (SEST 2021) tenutosi a Vaasa, Finland nel 6-8 September 2021) [10.1109/SEST50973.2021.9543232].

Detection of Anomalies in Household Appliances from Disaggregated Load Consumption

Marco Castangia;Enrico Macii;Edoardo Patti
2021

Abstract

The detection of anomalous power consumption in household appliances plays a key role for the optimization of grid operations and for reducing unwanted electrical absorptions in residential buildings. Smart Plugs, Smart Appliances and other appliance-level monitoring devices allow to continuously monitor the power consumption of individual appliances present in the house. This work is aimed at detecting electrical anomalies in household appliances by analyzing the disaggregated load consumption derived from appliance-level monitoring devices. For this purpose, we implemented an anomaly detection framework which monitors the hourly energy consumption of three common sources of power absorption: the baseline, the fridge and the electrical devices. Here, we focused our analysis on two kinds of anomalies: single-point deviations and anomalous trends. The analysis of single-point deviations allowed us to identify short-term power peaks due either to unexpected electrical faults or sudden variations in end-users routines. The analysis of anomalous trends revealed several cases in which the end-users gradually increased their ordinary power consumption profile towards more energy-intensive practices. In summary, the results of our work showed that the power consumption derived from appliance-level load monitoring can be used to detect several anomalous power consumption in household appliances.
File in questo prodotto:
File Dimensione Formato  
SEST_2021__NILM-noCR.pdf

accesso aperto

Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: Pubblico - Tutti i diritti riservati
Dimensione 5.25 MB
Formato Adobe PDF
5.25 MB Adobe PDF Visualizza/Apri
Detection_of_Anomalies_in_Household_Appliances_from_Disaggregated_Load_Consumption.pdf

accesso riservato

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 1.89 MB
Formato Adobe PDF
1.89 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2921912