This work is focused on the study of the collapse of the Morandi bridge in Genoa. From the free-available data from literature, a numerical model of the structure has been prepared. Since no monitoring measurements or laboratory tests on materials were available, it was not possible to carry out an effective validation process of the model. However, the refined numerical approach and the collected design conditions allow a reasonable heuristic study to be carried out, to outline potential structural behaviors and responses to external perturbations. The analysis identified two critical aspects that may have affected the structural response. Both are related to the time variable that has likely affected both the operating conditions of the bridge and its loading capacity. Besides, structural solutions for stays (e.g. continuous over saddles) and the essentially static determinate scheme may have also affected the response.

Safety of existing infrastructures: the collapse of the Morandi bridge in Genoa / Domaneschi, Marco; Cimellaro, Gian Paolo; Morgese, Maurizio; Ansari, Farhad. - ELETTRONICO. - (2021), pp. 1499-1505. (Intervento presentato al convegno Proceedings of the Tenth International Conference on Bridge Maintenance, Safety and Management, IABMAS 2020 tenutosi a Sapporo, Japan nel 11 April 2021 through 15 April 2021) [10.1201/9780429279119-205].

Safety of existing infrastructures: the collapse of the Morandi bridge in Genoa

Domaneschi, Marco;Cimellaro, Gian Paolo;Ansari, Farhad
2021

Abstract

This work is focused on the study of the collapse of the Morandi bridge in Genoa. From the free-available data from literature, a numerical model of the structure has been prepared. Since no monitoring measurements or laboratory tests on materials were available, it was not possible to carry out an effective validation process of the model. However, the refined numerical approach and the collected design conditions allow a reasonable heuristic study to be carried out, to outline potential structural behaviors and responses to external perturbations. The analysis identified two critical aspects that may have affected the structural response. Both are related to the time variable that has likely affected both the operating conditions of the bridge and its loading capacity. Besides, structural solutions for stays (e.g. continuous over saddles) and the essentially static determinate scheme may have also affected the response.
2021
978-036723278-8
9780429279119
File in questo prodotto:
File Dimensione Formato  
Morandi IABMAS_T100385.pdf

accesso riservato

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 683.36 kB
Formato Adobe PDF
683.36 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Morandi IABMAS_T100385.pdf

accesso riservato

Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 683.36 kB
Formato Adobe PDF
683.36 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2914820