Purpose: Present (i) an infrared (IR)-based Process Analytical Technology (PAT) installed in a lab-scale freeze-dryer and (ii) a micro freeze-dryer (MicroFD®) as effective tools for freeze-drying design space calculation of the primary drying stage. Methods: The case studies investigated are the freeze-drying of a crystalline (5% mannitol) and of an amorphous (5% sucrose) solution processed in 6R vials. The heat (Kv) and the mass (Rp) transfer coefficients were estimated: tests at 8, 13 and 26 Pa were carried out to assess the chamber pressure effect on Kv. The design space of the primary drying stage was calculated using these parameters and a well-established model-based approach. The results obtained using the proposed tools were compared to the ones in case Kv and Rp were estimated in a lab-scale unit through gravimetric tests and a thermocouple-based method, respectively. Results: The IR-based method allows a non-gravimetric estimation of the Kv values while with the micro freeze-dryer gravimetric tests require a very small number of vials. In both cases, the obtained values of Kv and Rp, as well as the resulting design spaces, were all in very good agreement with those obtained in a lab-scale unit through the gravimetric tests (Kv) and the thermocouple-based method (Rp). Conclusions: The proposed tools can be effectively used for design space calculation in substitution of other well-spread methods. Their advantages are mainly the less laborious Kv estimation process and, as far as the MicroFD® is concerned, the possibility of saving time and formulation material when evaluating Rp.

Micro Freeze-Dryer and Infrared-Based PAT: Novel Tools for Primary Drying Design Space Determination of Freeze-Drying Processes / Harguindeguy, M.; Fissore, D.. - In: PHARMACEUTICAL RESEARCH. - ISSN 0724-8741. - STAMPA. - 38:4(2021), pp. 707-719. [10.1007/s11095-021-03023-x]

Micro Freeze-Dryer and Infrared-Based PAT: Novel Tools for Primary Drying Design Space Determination of Freeze-Drying Processes

Harguindeguy M.;Fissore D.
2021

Abstract

Purpose: Present (i) an infrared (IR)-based Process Analytical Technology (PAT) installed in a lab-scale freeze-dryer and (ii) a micro freeze-dryer (MicroFD®) as effective tools for freeze-drying design space calculation of the primary drying stage. Methods: The case studies investigated are the freeze-drying of a crystalline (5% mannitol) and of an amorphous (5% sucrose) solution processed in 6R vials. The heat (Kv) and the mass (Rp) transfer coefficients were estimated: tests at 8, 13 and 26 Pa were carried out to assess the chamber pressure effect on Kv. The design space of the primary drying stage was calculated using these parameters and a well-established model-based approach. The results obtained using the proposed tools were compared to the ones in case Kv and Rp were estimated in a lab-scale unit through gravimetric tests and a thermocouple-based method, respectively. Results: The IR-based method allows a non-gravimetric estimation of the Kv values while with the micro freeze-dryer gravimetric tests require a very small number of vials. In both cases, the obtained values of Kv and Rp, as well as the resulting design spaces, were all in very good agreement with those obtained in a lab-scale unit through the gravimetric tests (Kv) and the thermocouple-based method (Rp). Conclusions: The proposed tools can be effectively used for design space calculation in substitution of other well-spread methods. Their advantages are mainly the less laborious Kv estimation process and, as far as the MicroFD® is concerned, the possibility of saving time and formulation material when evaluating Rp.
File in questo prodotto:
File Dimensione Formato  
100_PR_2021_vol38.pdf

accesso aperto

Descrizione: Versione editoriale
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 1.15 MB
Formato Adobe PDF
1.15 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2896194