On August 14, 2018, a few spans of the cable-stayed viaduct crossing the Polcevera river (Genoa, Italy) collapsed, causing tens of fatalities along with considerable material damage and hundreds of people displaced. The viaduct, as well as many others belonging to the national road network, was built in the second half of the last Century and has been in service for over fifty years. The bridge has experienced a dramatic increase in the heavy lorries traffic, together with degradation that developed much faster than expected due to the aggressive environment. In the present paper, a possible scenario is proposed to put into evidence how the combined effect of fatigue at very-high number of cycles and corrosion could have been responsible for the sudden failure of one of the strands and the subsequent collapse of the so-called balanced system conceived by the designer Morandi. Our purpose is to warn the scientific community and the public administrations about the combined effects of low amplitude cycle fatigue and corrosion, which can be dangerously underestimated in the safety assessment of last Century bridges asset.

The collapse of the Morandi’s bridge: remarks about fatigue and corrosion / Invernizzi, S.; Montagnoli, F.; Carpinteri, A.. - ELETTRONICO. - (2020), pp. 1040-1047. (Intervento presentato al convegno Synergy of Culture and Civil Engineering – History and Challenges tenutosi a Wrocław (Poland) nel October 7-9, 2020).

The collapse of the Morandi’s bridge: remarks about fatigue and corrosion

S. Invernizzi;F. Montagnoli;A. Carpinteri
2020

Abstract

On August 14, 2018, a few spans of the cable-stayed viaduct crossing the Polcevera river (Genoa, Italy) collapsed, causing tens of fatalities along with considerable material damage and hundreds of people displaced. The viaduct, as well as many others belonging to the national road network, was built in the second half of the last Century and has been in service for over fifty years. The bridge has experienced a dramatic increase in the heavy lorries traffic, together with degradation that developed much faster than expected due to the aggressive environment. In the present paper, a possible scenario is proposed to put into evidence how the combined effect of fatigue at very-high number of cycles and corrosion could have been responsible for the sudden failure of one of the strands and the subsequent collapse of the so-called balanced system conceived by the designer Morandi. Our purpose is to warn the scientific community and the public administrations about the combined effects of low amplitude cycle fatigue and corrosion, which can be dangerously underestimated in the safety assessment of last Century bridges asset.
2020
978-3-85748-169-7
File in questo prodotto:
File Dimensione Formato  
WROCLAW_2020_Proceedings INVERNIZZI.pdf

accesso riservato

Descrizione: Paper pubblicato
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 377.78 kB
Formato Adobe PDF
377.78 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.