This paper presents a sensorized belt with four fully integrated pressure-touch sensors. We propose a very-low complexity sensor able to measure a pressure variation (up to 4 MPa) and to identify with accuracy a contact event at around 10 kPa. The overall pressure/touch sensor integrates a transducer, based on piezo capacitive material, coupled with a read-out circuit designed around a ring-oscillator. This converts the capacitance variation of the transducer into a quasi-digital signal characterized by a frequency range of 36.3-270 kHz with a very low standard deviation (2.3 kHz) and a sensitivity of 2.2 Hz/Pa. The tight integration of the electronics with the transducer results in a very compact all-in-one sensor system (overall size is 20 mm × 20 mm × 10 mm). Further, a major benefit of a low complexity design is the low power consumption, measured to be ∼370 μW. Based on a quasi-digital approach (event-driven), the system is well suited for impulse-based wireless communication.
A quasi-digital pressure/touch sensor prototype for orbital targets contact event monitoring / Stoppa, M.; Ros, P. M.; Crepaldi, M.; Chiolerio, A.; Demarchi, D.. - 2016-:(2016), pp. 2843-2846. ((Intervento presentato al convegno 2016 IEEE International Symposium on Circuits and Systems, ISCAS 2016 tenutosi a Montreal's Sheraton Centre, can nel 2016 [10.1109/ISCAS.2016.7539185].
A quasi-digital pressure/touch sensor prototype for orbital targets contact event monitoring
Ros P. M.;Demarchi D.
2016
Abstract
This paper presents a sensorized belt with four fully integrated pressure-touch sensors. We propose a very-low complexity sensor able to measure a pressure variation (up to 4 MPa) and to identify with accuracy a contact event at around 10 kPa. The overall pressure/touch sensor integrates a transducer, based on piezo capacitive material, coupled with a read-out circuit designed around a ring-oscillator. This converts the capacitance variation of the transducer into a quasi-digital signal characterized by a frequency range of 36.3-270 kHz with a very low standard deviation (2.3 kHz) and a sensitivity of 2.2 Hz/Pa. The tight integration of the electronics with the transducer results in a very compact all-in-one sensor system (overall size is 20 mm × 20 mm × 10 mm). Further, a major benefit of a low complexity design is the low power consumption, measured to be ∼370 μW. Based on a quasi-digital approach (event-driven), the system is well suited for impulse-based wireless communication.File | Dimensione | Formato | |
---|---|---|---|
MottoRos-Aquasi.pdf
non disponibili
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
455.21 kB
Formato
Adobe PDF
|
455.21 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2858365