The home automation system to control the climatic health in confined environments is the subject of this article. The standard UNI EN ISO 7730:2006 classifies the conditions of moderate confined environments by three categories according to the PMV index. The comfort sensation is mainly affected by four variables: air temperature, mean radiant temperature, air velocity, relative humidity. They are all mechanical and thermal quantities therefore they are measured through the same measurement method. In evaluating the PMV index two more variables are taken into account: metabolism and clothing insulation. They can be evaluated by different accuracy levels. Their indirect measure is subjected to more uncertainty than the above four measuring parameters and the distribution is typically non-Gaussian. The paper analyses the uncertainty in PMV measuring through the Monte Carlo simulation. The proposed study identifies the different weight of independent variables showing as their uncertainty, particularly those referred to metabolism and clothing insulation, affects considerably the final values for classifying the moderate environments.

Home automation systems and PMV classification for moderate confined environments / Bertetto, A. M.; Cadeddu, A.; Niccolini, G.; Di Pilla, L.; Ricciu, R.. - STAMPA. - 1:(2015), pp. 1-5. (Intervento presentato al convegno 23rd International Conference on Robotics in Alpe-Adria-Danube Region, IEEE RAAD 2014 tenutosi a Smolenice Castle, svk nel 3-5 settembre, 2014) [10.1109/RAAD.2014.7002277].

Home automation systems and PMV classification for moderate confined environments

Niccolini G.;
2015

Abstract

The home automation system to control the climatic health in confined environments is the subject of this article. The standard UNI EN ISO 7730:2006 classifies the conditions of moderate confined environments by three categories according to the PMV index. The comfort sensation is mainly affected by four variables: air temperature, mean radiant temperature, air velocity, relative humidity. They are all mechanical and thermal quantities therefore they are measured through the same measurement method. In evaluating the PMV index two more variables are taken into account: metabolism and clothing insulation. They can be evaluated by different accuracy levels. Their indirect measure is subjected to more uncertainty than the above four measuring parameters and the distribution is typically non-Gaussian. The paper analyses the uncertainty in PMV measuring through the Monte Carlo simulation. The proposed study identifies the different weight of independent variables showing as their uncertainty, particularly those referred to metabolism and clothing insulation, affects considerably the final values for classifying the moderate environments.
2015
978-1-4799-6798-8
978-1-4799-6797-1
978-80-227-4219-1
File in questo prodotto:
File Dimensione Formato  
raad2014_submission_58_Home Autom.pdf

non disponibili

Descrizione: Articolo principale
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 718.69 kB
Formato Adobe PDF
718.69 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Home Automation Systems and PMV Classification forRAAD 2014.pdf

accesso aperto

Descrizione: Ultima versione degli autori
Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 380.03 kB
Formato Adobe PDF
380.03 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2838235