Electrochemical Impedance Spectroscopy (EIS) is commonly used for the diagnosis of electrochemical energy accumulators, for example Li-Ion batteries in Electric and Hybrid Vehicles. Measuring the impedance in a wide frequency range, it is possible to investigate on the modifications of the internal electrochemical cell process, evaluating its current state of life. EIS test consists of the excitation of the battery, or cell, with a defined current signal, and then measuring the cell voltage, the frequency response of the system is computed. The classical EIS test, based on the excitation with a frequency controlled sine wave in input, requires expensive instruments and long time test procedures; therefore it has many problems on the integration on the embedded systems. In this paper, a pseudo random square signal, which shows a simply hardware implementation, is used as excitation signal input on the cell for the impedance evaluation. The effectiveness of the method has been validated based on simulation test, in order to obtain good results in terms of impedance estimation accuracy, minimizing time duration and energy consumption.
Electrochemical Impedance Spectroscopy of Li-Ion battery on-board the Electric Vehicles based on Fast nonparametric identification method / Locorotondo, E; Pugi, L; Berzi, L; Pierini, M; Scavuzzo, S; Ferraris, A; Airale, A; Carello, M. - ELETTRONICO. - (2019). (Intervento presentato al convegno 19th IEEE International Conference on Environment and Electrical Engineering and 2019 IEEE Industrial and Commercial Power Systems Europe, EEEIC/I and CPS Europe tenutosi a Genova nel 11-14 June 2019) [10.1109/EEEIC.2019.8783625].
Electrochemical Impedance Spectroscopy of Li-Ion battery on-board the Electric Vehicles based on Fast nonparametric identification method
Scavuzzo, S;Ferraris, A;Airale, A;Carello, M
2019
Abstract
Electrochemical Impedance Spectroscopy (EIS) is commonly used for the diagnosis of electrochemical energy accumulators, for example Li-Ion batteries in Electric and Hybrid Vehicles. Measuring the impedance in a wide frequency range, it is possible to investigate on the modifications of the internal electrochemical cell process, evaluating its current state of life. EIS test consists of the excitation of the battery, or cell, with a defined current signal, and then measuring the cell voltage, the frequency response of the system is computed. The classical EIS test, based on the excitation with a frequency controlled sine wave in input, requires expensive instruments and long time test procedures; therefore it has many problems on the integration on the embedded systems. In this paper, a pseudo random square signal, which shows a simply hardware implementation, is used as excitation signal input on the cell for the impedance evaluation. The effectiveness of the method has been validated based on simulation test, in order to obtain good results in terms of impedance estimation accuracy, minimizing time duration and energy consumption.File | Dimensione | Formato | |
---|---|---|---|
143.pdf
non disponibili
Descrizione: Articolo Principale versione Post Print
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
635.69 kB
Formato
Adobe PDF
|
635.69 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
LAST_draFT_paperEEIC2019_IRIS.pdf
accesso aperto
Descrizione: Articolo Principale Versione pre print
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
PUBBLICO - Tutti i diritti riservati
Dimensione
675.32 kB
Formato
Adobe PDF
|
675.32 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2816964