Background: The lipid content of the chylomicrons is a key biomarker and risk factor of cardiovascular diseases and for the understanding of obesity. A high throughput determination of chylomicrons in human blood plasma is outlined. Methods. The new method, which uses a combination of Nuclear Magnetic Resonance (NMR) analysis and multivariate calibration analysis (chemometrics), is based on a correlation analysis towards the established standard method (ultracentrifugation and colorimetric test kit) and enables extraordinarily fast, inexpensive, and robust prediction of triglyceride (TG) content in chylomicrons. It is the position and shape of the complex lipid methylene resonance band that determines the chylomicron TG status and this information is extracted by the multivariate regression method. Results: The resulting method is a relatively simple multivariate model that facilitates parsimonious and accurate prediction of chylomicron lipids from NMR spectra of blood. The chemometric model predicts the chylomicron TG content with a correlation coefficient (R) of 0.96 when plotted against density gradient ultracentrifugation data. Conclusions: The new rapid method facilitates large scale clinical and nutritional trials with inclusion of diagnostics of chylomicron status and thus creates new opportunities for research in lifestyle diseases and obesity. © 2010 Savorani et al; licensee BioMed Central Ltd.

High throughput prediction of chylomicron triglycerides in human plasma by nuclear magnetic resonance and chemometrics / Savorani, F.; Kristensen, M.; Larsen, F. H.; Astrup, A.; Engelsen, S. B.. - In: NUTRITION & METABOLISM. - ISSN 1743-7075. - ELETTRONICO. - 7:1(2010), p. 43. [10.1186/1743-7075-7-43]

High throughput prediction of chylomicron triglycerides in human plasma by nuclear magnetic resonance and chemometrics

Savorani F.;
2010

Abstract

Background: The lipid content of the chylomicrons is a key biomarker and risk factor of cardiovascular diseases and for the understanding of obesity. A high throughput determination of chylomicrons in human blood plasma is outlined. Methods. The new method, which uses a combination of Nuclear Magnetic Resonance (NMR) analysis and multivariate calibration analysis (chemometrics), is based on a correlation analysis towards the established standard method (ultracentrifugation and colorimetric test kit) and enables extraordinarily fast, inexpensive, and robust prediction of triglyceride (TG) content in chylomicrons. It is the position and shape of the complex lipid methylene resonance band that determines the chylomicron TG status and this information is extracted by the multivariate regression method. Results: The resulting method is a relatively simple multivariate model that facilitates parsimonious and accurate prediction of chylomicron lipids from NMR spectra of blood. The chemometric model predicts the chylomicron TG content with a correlation coefficient (R) of 0.96 when plotted against density gradient ultracentrifugation data. Conclusions: The new rapid method facilitates large scale clinical and nutritional trials with inclusion of diagnostics of chylomicron status and thus creates new opportunities for research in lifestyle diseases and obesity. © 2010 Savorani et al; licensee BioMed Central Ltd.
File in questo prodotto:
File Dimensione Formato  
1743-7075-7-43.pdf

accesso aperto

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 1.1 MB
Formato Adobe PDF
1.1 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2815642