For a decade to now, lighting with LED lamp technology has rapidly established itself in the market, both for domestic use and for industrial use, becoming in fact a viable alternative to fluorescent lamp technology. Industrial research interests focus on this LED lamp technology, which is steadily in development, presenting continuous improvements and considerable advantages compared to the fluorescent lamps. It should be noted that both technologies introduce a high harmonic content in the power supply network, and therefore represent a non-linear load for the mains. The present work aims to analyze and study the electrical and photometric characteristics of the two technologies. For this purpose eight lamp types, four CFL and four LED lamps are tested, through laboratory measurements and detailed analyses. The photometric and electrical quantities of the lamps are then detected, and subsequently the variations undergone by these quantities with the aging of the lamps are verified and discussed. The measurements of the photometric quantities are performed according to the EN 13032-1: 2004 standard, and the tests on the electrical quantities aim to evaluate the harmonic content, and check if it meets the IEC 61000-3-2 standard.

Effects of the aging time on CFL and LED lamps: Experimental tests on the electrical and photometric quantities / Di Mauro, S.; Raciti, A.; Rizzo, S. A.; Susinni, G.; Musumeci, S.. - ELETTRONICO. - (2018), pp. 1-6. (Intervento presentato al convegno 2018 110th AEIT International Annual Conference, AEIT 2018 tenutosi a Bari, Italy nel October 2018) [10.23919/AEIT.2018.8577281].

Effects of the aging time on CFL and LED lamps: Experimental tests on the electrical and photometric quantities

Musumeci S.
2018

Abstract

For a decade to now, lighting with LED lamp technology has rapidly established itself in the market, both for domestic use and for industrial use, becoming in fact a viable alternative to fluorescent lamp technology. Industrial research interests focus on this LED lamp technology, which is steadily in development, presenting continuous improvements and considerable advantages compared to the fluorescent lamps. It should be noted that both technologies introduce a high harmonic content in the power supply network, and therefore represent a non-linear load for the mains. The present work aims to analyze and study the electrical and photometric characteristics of the two technologies. For this purpose eight lamp types, four CFL and four LED lamps are tested, through laboratory measurements and detailed analyses. The photometric and electrical quantities of the lamps are then detected, and subsequently the variations undergone by these quantities with the aging of the lamps are verified and discussed. The measurements of the photometric quantities are performed according to the EN 13032-1: 2004 standard, and the tests on the electrical quantities aim to evaluate the harmonic content, and check if it meets the IEC 61000-3-2 standard.
2018
978-888723740-5
File in questo prodotto:
File Dimensione Formato  
AEIT_2018_08577281.pdf

non disponibili

Descrizione: Articolo
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 261.39 kB
Formato Adobe PDF
261.39 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2788219