The paper presents the lumped parameter model of a hydraulic winch developed in the Simcenter Amesim environment. It includes a detailed model of a load sensing direction control valve and of an overcentre valve for controlling an orbit motor with holding brake. The model of the winch, validated on a test rig in terms of pressure drop across the motor, has been used for analyzing different control strategies for obtaining the same velocity profile of the shaft and the total hydraulic energy supplied by the load sensing pump has been evaluated. As a first step, the independent metering architecture has been implemented. An additional simplification of the system was the removal of the local pressure compensator and the control of the speed in a closed loop using as feedback signal the output of an integrated tachometer. As a last step, the overcentre valve has been removed and the overrunning load has been imposed by a meter-out control of the flow rate.

Simulation and testing of a hydraulic winch / Rundo, Massimo; Corvaglia, Alessandro. - ELETTRONICO. - 2201:(2019), p. 020135. (Intervento presentato al convegno 74° Congresso Nazionale ATI tenutosi a Modena nel 11-13 settembre 2019) [10.1063/1.5138868].

Simulation and testing of a hydraulic winch

Rundo, Massimo;Corvaglia, Alessandro
2019

Abstract

The paper presents the lumped parameter model of a hydraulic winch developed in the Simcenter Amesim environment. It includes a detailed model of a load sensing direction control valve and of an overcentre valve for controlling an orbit motor with holding brake. The model of the winch, validated on a test rig in terms of pressure drop across the motor, has been used for analyzing different control strategies for obtaining the same velocity profile of the shaft and the total hydraulic energy supplied by the load sensing pump has been evaluated. As a first step, the independent metering architecture has been implemented. An additional simplification of the system was the removal of the local pressure compensator and the control of the speed in a closed loop using as feedback signal the output of an integrated tachometer. As a last step, the overcentre valve has been removed and the overrunning load has been imposed by a meter-out control of the flow rate.
2019
978-073541938-4
File in questo prodotto:
File Dimensione Formato  
1.5138868.pdf

Open Access dal 18/12/2020

Descrizione: Articolo principale
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 1.16 MB
Formato Adobe PDF
1.16 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2782377