While power networks evolve towards the new concept of smart grids, with the proliferation of power electronics embedded systems and distributed generation, the insurgence of system unbalance and voltage harmonic distortion, become more and more frequent. Also, often a noisy voltage sampling system can produce offsets in measurements. Such imperfections bring challenges to the phase identification using a traditional phase-lock loop (PLL), utilized in the control of all grid connected converters. However, since the imperfections lead to periodic harmonics in the corresponding dq-axis voltages, the repetitive controller (RC) can be useful for harmonic suppression. This paper presents a three-phase PLL using a feed-back RC. Specially, a novel running mean filter has been added to minimize the interaction between RC and the Proportional-Integral (PI) controller in the PLL. Simulation results show that the proposed PLL can track the phase of the three-phase voltage without being influenced by harmonic distortion.

A Novel Phase-lock Loop with Feed-back Repetitive Controller for Robustness to Periodic Disturbance in Three-phase Systems / Tang, Mi; Bifaretti, Stefano; Pipolo, Sabino; Odhano, Shafiq; Zanchetta, Pericle. - ELETTRONICO. - (2018), pp. 2691-2697. (Intervento presentato al convegno 10th Annual IEEE Energy Conversion Congress and Exposition, ECCE 2018 tenutosi a usa nel 2018) [10.1109/ECCE.2018.8557691].

A Novel Phase-lock Loop with Feed-back Repetitive Controller for Robustness to Periodic Disturbance in Three-phase Systems

Odhano, Shafiq;
2018

Abstract

While power networks evolve towards the new concept of smart grids, with the proliferation of power electronics embedded systems and distributed generation, the insurgence of system unbalance and voltage harmonic distortion, become more and more frequent. Also, often a noisy voltage sampling system can produce offsets in measurements. Such imperfections bring challenges to the phase identification using a traditional phase-lock loop (PLL), utilized in the control of all grid connected converters. However, since the imperfections lead to periodic harmonics in the corresponding dq-axis voltages, the repetitive controller (RC) can be useful for harmonic suppression. This paper presents a three-phase PLL using a feed-back RC. Specially, a novel running mean filter has been added to minimize the interaction between RC and the Proportional-Integral (PI) controller in the PLL. Simulation results show that the proposed PLL can track the phase of the three-phase voltage without being influenced by harmonic distortion.
2018
9781479973118
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2729270
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo