The “Paraboloide” of Casale (Italy) was built around 1926 to be a clinker warehouse, and nowadays is a relevant example of the Italian concrete industrial heritage. The thin parabolic vault and the construction methodology are as innovative as other much better-known realizations of the dawn of the reinforced concrete era. Thanks to the adoption of LiDAR (Laser Imaging Detection and Ranging) technology, a detailed three-dimensional survey of the structure geometry has been carried out, including not only the emerging parabolic vault, but also the complex and very interesting underground structure. Homogeneous level of precision and continuous metric information of each, straight and curved, structural elements turned out to be crucial to the correct identification of design principles and construction solutions adopted at the time of the construction, which is mandatory for the correct refurbishment of the “Paraboloide”. The decay analysis of the most difficult regions to reach was carried out combining the laser survey information with a series of terrestrial photogrammetric pictures. A finite element analysis of the structure, accounting for the presence of reinforcements, was carried out in order to assess the initial and the present structural safety. In addition, the principal intervention criteria, both related to structural safety requirements and conservation prescriptions, are briefly summarized.

Survey, Assessment and Conservation of Post-industrial Cultural Heritage: The Case of the Thin Concrete Vault in Casale, Italy / Invernizzi, Stefano; Spanò, Antonia; Chiabrando, Filiberto. - STAMPA. - 18:(2019), pp. 1401-1409. (Intervento presentato al convegno 11th International Conference on Structural Analysis of Historical Constructions tenutosi a Cuzco, Perù nel 11-13 Settembre 2018) [10.1007/978-3-319-99441-3_150].

Survey, Assessment and Conservation of Post-industrial Cultural Heritage: The Case of the Thin Concrete Vault in Casale, Italy

Invernizzi, Stefano;Spanò, Antonia;Chiabrando, Filiberto
2019

Abstract

The “Paraboloide” of Casale (Italy) was built around 1926 to be a clinker warehouse, and nowadays is a relevant example of the Italian concrete industrial heritage. The thin parabolic vault and the construction methodology are as innovative as other much better-known realizations of the dawn of the reinforced concrete era. Thanks to the adoption of LiDAR (Laser Imaging Detection and Ranging) technology, a detailed three-dimensional survey of the structure geometry has been carried out, including not only the emerging parabolic vault, but also the complex and very interesting underground structure. Homogeneous level of precision and continuous metric information of each, straight and curved, structural elements turned out to be crucial to the correct identification of design principles and construction solutions adopted at the time of the construction, which is mandatory for the correct refurbishment of the “Paraboloide”. The decay analysis of the most difficult regions to reach was carried out combining the laser survey information with a series of terrestrial photogrammetric pictures. A finite element analysis of the structure, accounting for the presence of reinforcements, was carried out in order to assess the initial and the present structural safety. In addition, the principal intervention criteria, both related to structural safety requirements and conservation prescriptions, are briefly summarized.
2019
978-3-319-99440-6
978-3-319-99441-3
File in questo prodotto:
File Dimensione Formato  
00180150.pdf

non disponibili

Descrizione: Paper
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 1.75 MB
Formato Adobe PDF
1.75 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2723537
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo